10 technical data, Technical data – Baumer AMG 71 Benutzerhandbuch

Seite 29

Advertising
background image

MB186

amg71_mb (12A1)

26

Technical data

10

10

Technical data

10.1

General data

Voltage supply:

730 VDC

Initializing time:

≤200 ms after power on

Operating speed:

≤5,000 rpm

Admitted shaft load:

≤50 N axial

≤120 N radial

Rotor moment of inertia:

25 gcm

2

Vibration resistance:

100 m/s

2

≈ 10 g

IEC 60068-2-6: 2007

(10-2,000 Hz)

Shock resistance:

1,000 m/s

2

≈ 100 g

IEC 60068-2-27: 2008

(6 ms)

Operating torque:

2 Ncm

Protection IEC 60529:

IP 66

Operating temperature:

-20°C+85°C

(restricted in potentially explosive environments, see section 2)

Weight approx.:

350 g

EMC according to:

EN 61000-6-2: 2005 (interference immunity)

EN 61000-6-4: 2007 (emitted interference)

10.5

SSI Interface

Steps per turn:

8192 / 13 bit

Number of turns:

4096 / 12 bit,

65536 / 16 bit (option)

Clock frequency:

100800 kHz

Mark space ratio 1:1

Consumption w/o load:

≤100 mA per interface

Code:

Gray or binary

Code sequence:

CW default, programmable

Diagnostic functions:

LED failure, self-diagnosis,

code continuity check

Connection:

Terminal cover

10.6

Additional incremental part

Output circuit:

Sine 1 Vpp

Resolution (steps/turn):

2,048

Spectrum:

200 kHz (-3 dB)

Harmonics share approx.:

-50 dB

Offset sine/cosine amplitude:

≤20 mV

Overlaying constant share:

≤20 mV

Connection:

Terminal cover

Advertising