5 led status display, value of output «system ok, Led status display, value of output «system ok – Baumer MIR3000F Benutzerhandbuch
Seite 23

MB232 - 11111219
Baumer_MIR3000F_II_DE-EN (14A2)
20
Elektrischer Anschluss / Electrical connection
6
6.5
LED status display, value of output «System OK+»
LED status
display
Value of output
«
System OK+»
Description
Off
0 (LOW)
Sensor without power supply or total failure.
Green
constant
1 (HIGH)
Initialization of position signal finished successfully.
No rotation.
Flash light
green
1 (HIGH)
Initialization of position signal finished successfully.
Rotating shaft.
Flash light
green/yellow
1 (HIGH)
Initialization of position signal not yet finished.
Belt lock must pass sensor head twice in same direction.
Incremental and speed signals are available immediately after
switching on.
Yellow constant
1 (HIGH)
“Warning Level 1”:
At least one of the following events detected:
- Air gap too big
- Ambient temperature >90°C (>194°F) or <-40°C (-40°F)
- Mechanically valid maximum speed is exceeded by +25%
- Supply voltage >30 VDC oder <4,75 VDC
- Shaft diameter is in area B (see section 4.3)
Output signals are valid.
Signals maybe out of specifications.
Flash light
yellow/red
1 (HIGH)
“Warning Level 2”:
At least one of the following events detected:
- Air gap too big
- Ambient temperature >100°C (>212°F) or <-45°C (-49°F)
- Allowed maximum speed is exceeded by +50%
Output signals are valid.
Maybe they are out of specifications.
Flash light red
0 (LOW)
“Error”:
Shaft is rotating, wrong pulses per revolution detected.
Possible reasons:
- False shaft diameter (area C, see section 4.3)
- False length of magnetic belt
- Belt lock gap too big
Red
constant
0 (LOW)
“Error”:
Possible reasons:
- False shaft diameter (area C, see section 4.3)
- Shaft stands still
- Magnetic belt can not be detected
- Output overloaded or short-circuited
- Supply voltage <4,3 VDC