5 led status display, value of output «system ok, Led status display, value of output «system ok – Baumer MIR3000F Benutzerhandbuch

Seite 23

Advertising
background image

MB232 - 11111219

Baumer_MIR3000F_II_DE-EN (14A2)

20

Elektrischer Anschluss / Electrical connection

6

6.5

LED status display, value of output «System OK+»

LED status

display

Value of output

«

System OK+»

Description

Off

0 (LOW)

Sensor without power supply or total failure.

Green

constant

1 (HIGH)

Initialization of position signal finished successfully.

No rotation.

Flash light

green

1 (HIGH)

Initialization of position signal finished successfully.

Rotating shaft.

Flash light

green/yellow

1 (HIGH)

Initialization of position signal not yet finished.

Belt lock must pass sensor head twice in same direction.

Incremental and speed signals are available immediately after

switching on.

Yellow constant

1 (HIGH)

“Warning Level 1”:
At least one of the following events detected:
- Air gap too big

- Ambient temperature >90°C (>194°F) or <-40°C (-40°F)

- Mechanically valid maximum speed is exceeded by +25%

- Supply voltage >30 VDC oder <4,75 VDC

- Shaft diameter is in area B (see section 4.3)
Output signals are valid.

Signals maybe out of specifications.

Flash light

yellow/red

1 (HIGH)

“Warning Level 2”:
At least one of the following events detected:
- Air gap too big

- Ambient temperature >100°C (>212°F) or <-45°C (-49°F)

- Allowed maximum speed is exceeded by +50%
Output signals are valid.

Maybe they are out of specifications.

Flash light red

0 (LOW)

“Error”:
Shaft is rotating, wrong pulses per revolution detected.

Possible reasons:
- False shaft diameter (area C, see section 4.3)

- False length of magnetic belt

- Belt lock gap too big

Red

constant

0 (LOW)

“Error”:
Possible reasons:
- False shaft diameter (area C, see section 4.3)

- Shaft stands still

- Magnetic belt can not be detected

- Output overloaded or short-circuited

- Supply voltage <4,3 VDC

Advertising