8 technical data, 1 technical data - electrical ratings, 3 technical data - electrical ratings (sinewave) – Baumer MIR3000F Benutzerhandbuch
Seite 28: Technical data, Technical data - electrical ratings, Technical data - electrical ratings (square-wave), Technical data - electrical ratings (sinewave)

25
Baumer_MIR3000F_II_DE-EN (14A2)
MB232 - 11111219
8
Technical data
8
Technical data
8.1
Technical data - electrical ratings
• Voltage supply:
4.75...30 VDC
• Consumption w/o load:
≤300 mA (24 VDC)
• Initializing time:
≤1000 ms after power on
• Sensing method:
Magnetic
• Output signals:
A+, A-, B+, B-, R+, R-
• Status indicator:
Color-LED, «System OK» output
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approval:
CE
8.2
Technical data - electrical ratings (square-wave)
• Pulses per revolution:
512...131072
(As ordered)
• Phase shift:
90° ±2°
• Scan ratio:
45...55%
• Reference signal:
Zero pulse, width 90°
• Output frequency:
≤500 kHz (HTL)
≤2 MHz (TTL)
• Output stages:
HTL
TTL/RS422
(As ordered)
8.3
Technical data - electrical ratings (sinewave)
• Sinewave cycles per turn:
512...16384
(As ordered)
• Phase shift:
90° ±2°
• Reference signal:
Zero pulse, width 360°
• Output frequency:
≤500 kHz
• Output stage:
SinCos 1 Vpp