25

Baumer_MIR3000F_II_DE-EN (14A2)

MB232 - 11111219

8

Technical data

8

Technical data

8.1

Technical data - electrical ratings

Voltage supply:

4.75...30 VDC

Consumption w/o load:

≤300 mA (24 VDC)

Initializing time:

≤1000 ms after power on

Sensing method:

Magnetic

Output signals:

A+, A-, B+, B-, R+, R-

Status indicator:

Color-LED, «System OK» output

Interference immunity:

EN 61000-6-2:2005

Emitted interference:

EN 61000-6-3:2007/A1:2011

Approval:

CE

8.2

Technical data - electrical ratings (square-wave)

Pulses per revolution:

512...131072

(As ordered)

Phase shift:

90° ±2°

Scan ratio:

45...55%

Reference signal:

Zero pulse, width 90°

Output frequency:

≤500 kHz (HTL)

≤2 MHz (TTL)

Output stages:

HTL

TTL/RS422

(As ordered)

8.3

Technical data - electrical ratings (sinewave)

Sinewave cycles per turn:

512...16384

(As ordered)

Phase shift:

90° ±2°

Reference signal:

Zero pulse, width 360°

Output frequency:

≤500 kHz

Output stage:

SinCos 1 Vpp

Advertising