40

CITIZEN

8. DRAWER KICK-OUT CONNECTOR AND POWER CONNECTOR

8.1 Specifications of Drawer Kick-Out Connector (D-type Only)

(1) Drawer kick-out drive signal

The pulses specified by the BELL command(07h) are output.(Approx. 200 ms)

(2) Electrical characteristics

1) Drive voltage: 24 V DC
2) Drive current: 0.8 A at maximum

8.1.1 Connector’s Pin Configuration

No.

Signal

Function

1

FG

Frame Ground

2

DRAWER

Drawer drive signal

3
4

VDR

Drawer drive power

5
6

GND

Common ground on the circuit

Connector used

: TM5RJ3-66(HIROSE) or equivalent

Applicable connector : TM3P-66P(HIROSE) or equivalent

CAUTION

: • No output is made while printing.

• A solenoid used for the drawer should be of 36

or more. An output

current should be kept below 0.8 A. Otherwise, there is a danger of
trouble or burnout.

• This connector cannot be connected to a telephone line. Do not connect

other than the solenoid.

8.1.2 Drive Circuit