Power-on utilities, Power-on utility options, Media sensor calibration – AMT Datasouth Fastmark M3 Benutzerhandbuch
Seite 24

~ 24 ~
Power-ON Utilities
There are three power-ON utilities to set up and test printer hardware. These
utilities are activated by pressing the FEED button then turning on the printer
power simultaneously and release the button at different LED light indications.
Power-ON Utility options
Follow the steps below for different power-on utilities.
1.
Turn OFF the printer power button.
2.
Press down the FEED button then turn ON the power button .
3.
Release the power button when the LED color turns to amber,
continue pressing the FEED button .
4.
Release the FEED button when the green LED indicates the desired
function:
Media sensor calibration
Follow the steps below to calibrate the media sensor.
1.
Turn off the printer power.
2.
Hold on the FEED button then turn on the power button
3.
Release the power button when the LED color turns
amber, continue pressing the FEED button.
4.
Release the FEED button when the LED indicates
and blinking. The LED will sequence right to left, 5 blinks each.
5.
The printer will calibrate the sensor sensitivity.
Power on utilities
The following LED light pattern will determine the function:
LED
Functions
(Solid)
(5 blinks)
(5 blinks)
(5 blinks)
(Solid green)
1. Media sensor calibration
Release
2. Self-test and enter dump
mode
Release
3. Printer initialization
Release