Store cues from a DMX board:
The DMX values can also be programmed by means of a DMX console.
Enter the STANDALONE menu and navigate to CAPT DMX. Programm the DMX-values
with an external DMX-console. To capture the data press „ENTER“. The fixtures display
will show START CAPTURE. To insert, delete or reset use the keys of the control panel
of the fixture.Activate the standalone mode:
The standalone mode is activated in the menu STANDALONE, RUN.
To enter the functions press “ENTER” (keep it down) and press “ESC” in addtion.
The Sparx7 will execute sequence in a repeating loop.
To leave press “ESC” and hold it down and press “ENTER” in addition.
Operation in Master-Slave mode:
To set a fixture to slave-mode navigate to REMOTE.
To activate the slave funciton press “ENTER” (keep it down) and press “ESC” in addtion.
The display will show either REMOTE INACTIVE if no DMX-signal is being received or
REMOTE ACTIVE if a DMX-signal is being received.
To leave this fuction press “ESC” (keep it down) and press “ENTER” in addition. Connect
the Sparx7 with DMX cables.
Select STANDALONE/RUN with the master fixture. Start function by pressing “ENTER”
(keep it down) and pressing “ESC” in addition.
All connected fixtures will repeat the steps synchronized to the master fixture.
To leave the menu press “ESC” (keep it down) and press “ENTER” in addition.
If you realize that a fixture reacts inaccurate check if the display shows REMOTE ACTIVE.

Preload Demo:
The Sparx7 provides 20 pre-programmed Effects in the Preload demo menu. The user
can load it an change the values with MODIFY. A quick introducing in the effects of Sparx7
can be done.

4.7 INFO

The menu informs about the current software/firmware version. The non-resettable
TOT OPERATE TIME counter displays total hours of use since the Sparx7 was manu-
factured. Temperature readouts from the display panel (TEMP BASE LCD) and power
supply unit (TEMP BASE PS) in the base as well as the driver (TEMP HEAD DRV) and
LED PCB (TEMP HEAD LED) in the head are available. In each case, you can view the
current temperature and the maximum temperature reached since the readout was last
reset individually. The TEMP HEAD LEDs views the actual temperature of the single
LEDs.