IMPAC pyrometers IN 210 · IN 210/4 · IN 210/5

7

4

Mechanical Installation


Numerous accessories guarantee easy installation of the pyrometers. The following overview
shows a selection of suitable accessories. The available range with reference numbers is
listed on page 15.


5

Alignment to the measuring object


For exact measurement of the object temperature the pyrometer must be aligned correctly
onto the object. The instruments are not equipped with a sighting so that the aligning must be
done thermally. When measuring a hot object in front of a cooler background, it usually suf-
fices to align the pyrometer to achieve the highest temperature reading.

6

Optics


Depending on the application each type of series 210 pyrometers is equipped with one of the
below mentioned optics.

Note: The pyrometer can measure objects at any distance, but the object has to

be bigger or at least as big as the spot size of the pyrometer in the meas-
uring distance.

The following drawings show the pyrometer's spot sizes M in different measuring distances a.
The spot size M in a distance of a = 0 mm is 15 mm and corresponds to the aperture of the
sensor head (diameter of the objective), this value is used to calculate measuring distances in
intermediate distances, e.g. with the spot size calculator in the InfraWin software.

Adjustable

mounting support

Cooling jacket

with air purging

Air purge unit

Power supply C/Z;
100...240 V AC
 24 V DC

LED digital display with
integrated power supply for
2-wire pyrometers

HT 6000: portable

setup device;

connecting cable

USB adapter for

PC configuration and

online monitoring