4 class 05 – devicenet connection object, 5 class 40 (28hex) – motor data object, 5 class 40 (28 – NORD Drivesystems BU0080 Benutzerhandbuch

Seite 40: Motor data object

Advertising
background image

NORDAC DeviceNet Handbuch

40

BU 0080 DE

6.5.4

Class 05 – DeviceNet Connection Object

In diesem Objekt können die Einstellungen für jede aktive Verbindung ausgelesen werden:

Instanz 1: Expl.Message

Instanz 2: Polling

Instanz 3: Bit-Strobe

Instanz 4: COS/Cyclic

Inst Attr.

Beschreibung

Typ

Access

1 State

USINT

Get

2 Instance

Type

USINT

Get

3 transportClass_trigger

BYTE

Get

4 produced_connection_id

UINT

Get

5 consumed_connection_id

UINT

Get

6 initial_comm_characteristic

BYTE

Get

7 produced_connection_size

UINT

Get

8 consumed_connection_size

UINT

Get

9 expected_packet_rate

UINT

Get/Set

12 watchdog_timeout_action

USINT

Get

13 produced_con_path_length

UINT

Get

14 produced_connection_path EPATH

Get

15 consumed_con_path_length

UINT

Get

16 consumed_connection_path EPATH

Get

1-4

17 produced_inhibit_time

UINT

Get

6.5.5

Class 40 (28

hex

) – Motor Data Object

Über das Motor Data Object können Motorspezifische Daten eingestellt bzw. gelesen werden. Dieses Objekt
ist nur gültig, wenn das AC-Profil eingeschaltet ist (s.o.)!

Inst Attr.

Beschreibung

Typ

Access

3 Motor

Type

USINT

Get

6 Stator Strom [0,1A]

UINT

Get

7 Nennspannung

[V]

UINT

Get/Set

8 Nennleistung

[W]

UDINT

Get/Set

9 Nennfrequenz

UINT

Get/Set

1

12 Polzahl

UINT

Get

Advertising