Technical data

General data and operating conditions

3

47

LDCDS-CPC9100 DE/EN 1.0

3

Technical data

3.1

General data and operating conditions

Conformity and approval
Conformity

CE

EN 61000 6-2 (4)

EMC Directive for industrial premises

EN 55022, EN 55024 Equipment of information technology

Protection of persons and equipment
Enclosure

Housing

IP20

Front and housing

cover

IP54

Class of protection

1

Mounting conditions
Mounting place

19” control cabinet according to DIN 41494

Mounting position

horizontal

Ambient conditions
Climatic

Storage

without UPS

-10 ... +60 °C

with UPS

-10 ... +40 °C

Transport

without UPS

-10 ... +60 °C

with UPS

-10 ... +40 °C

Operation

dependent on the equipment ( 47)

Relative humidity

10 ... 90 %, non-condensing

Site altitude

< 3000 m amsl

Note!

The failure probability of an electronic component increases with the ambient

temperature to which the component is subjected. Regarding the

serviceability and reliability, particular attention should be paid to the cooling

of the device. For every application, you should take care to keep the heating

of the device as low as possible.

Permissible ambient temperatures

Basic device with

without UPS

with

UPS

40 W additional load by PCI

extensions

100 W additional load by PCI

extensions

[°C]

[°C]

Mobile Intel® Celeron D 3.2 GHz

5 ... 45

5 ... 40

5 ... 35

Intel® Core™ 2 Duo 1.8 GHz
Intel® Core™ 2 Duo 2.13 GHz

Advertising