Note!

The corresponding RAID system has to be set in the BIOS before the Windows

XP installation.

1. Switch on the IPC and call the BIOS settings.
2. Carry out the following settings in the BIOS:

– Advanced -> IDE Configuration -> Configure S-ATA#1 as RAID
– Boot -> Boot Device Priority -> 1st Boot Device [”actual CD-rom drive”]
– Exit -> Save Changes and Exit
During the boot-up process, the following message appears for 1/2 seconds: ””Intel(R)

RAID for Serial ATA - Raid Configuration Utility”

3. Press [Ctrl] + [I]
4. Check whether the SATA disks are detected and select ”1 Create RAID Volume”.
5. Enter the name of the RAID installation and press [Enter].
6. Select the desired RAID level.
7. For ”RAID0”: activate ”Strip Size”, then ”Create Volume”.
8. To close, select ”Exit”.

The system returns to the BIOS menu.

9. Select Exit - > ”Save Changes and Exit”.
10. Insert LDC-Windows-XP-DVD and follow the instructions of the Windows

installation.

11. Afterwards install the ”Intel Matrix Storage Console” from the LDC tool and driver

CD.
Further information can be found in the corresponding documentation.