Maintenance

6

56

LDCDS-CPC9100 DE/EN 1.0

6

Maintenance

Stop!

Short circuit and static discharges
The device contains components which can be destroyed in case of a short

circuit or static discharge.
It is especially dangerous if the device housing is opened during operation for

the exchange of the hot-swappable fan.
Possible consequences:

ƒ

The device or parts of it will be destroyed.

Protective measures:

ƒ

Before carrying out works on the device which do not need the device to be

switched on:

– Shut down and switch off the IPC.

– Unplug the mains plug.

– Open the housing and, if available, disconnect the battery pack. ( 55).

– Carry out the work.

ƒ

When opening the housing while a voltage is applied, be very careful and

carry out the work immediately. The following must be especially observed:

– Do not touch any current-carrying parts.

– Do not touch any rotating fan blades (risk of injury!).

– Make sure that no small parts fall into the device which would cause a

short circuit.

ƒ

All persons who work with printed-circuit boards must consider ESD

measures.

ƒ

Do not touch contacts of connectors.

ƒ

Only touch printed-circuit boards at contact-free areas and only position

them on suitable material (e.g. on ESD packaging or conductive foamed

material).

ƒ

Only transport and store printed-circuit boards in ESC packaging.