UPS software Lenze Digitec UPS

Installing software

7

61

LDCDS-CPC9100 DE/EN 1.0

UPS: Select the ”MPS1068/AUP-X-300-V4” type from the list
Execute program: While the UPS software counts down the seconds until shutdown in

case of a power failure, an external program can be started. Enter the program here

( 63).
Port: The UPS is connected factory-set to COM1.
If youset apermanent COM port, thestandard addressis acceptedautomatically. Ifyou

select the ”User-defined” entry, you can freely set the address within the range 0100h

to 03F8h using the arrows next to the address field. Changes are only effective after a

PC restart.
Shutdown:Defines the way the operating system is shut down. The ”shutdown”option

is set by default.
The ”Fast Shutdown” defines a forced shutdown of the operating system. All running

programs are closed without considering possible feedbacks and the system is shut

down. Caution: This setting may cause a data loss of the running applications!
Time until shutdown: Here you can set the time from power failure to system

shutdown in intervals of 15 seconds. At a maximum, two minutes can be set. If the

”Wait until battery-low signal” box is activated, the slider cannot be moved. In this

setting, the computer is buffered by the UPS as long as possible.
Time until notification:Here you can set a time from 0 to 10 seconds between the

power failure and the appearance of the message window. This can be helpful if

short-time supply failures occur and a message window is not to appear immediately.

3. Click Next.

The program now tries to verify the UPS. If the UPS is not recognised under the port

selected, please check the external RS232 cable connection from the computer to the

UPS and ensure that the UPS reallyis connectedto theport selected.The setupprogram

then again calls the dialog for the settings.
In order to activate the UPS software, Windows must be restarted.

4. Select ”Restart Windows now” and confirm with ”OK”.

The UPS software is now installed. Every time after windows has been started, the UPS

is activated automatically.