Operating plan – Baumer TA202 Benutzerhandbuch

Seite 14

Advertising
background image

TA202

14 www.baumer.com

8. Operating plan

Line Default Settings

Description Outline

01 0

F1 - Tacho Display F1

02 0

F2 - Tacho Display F2

03 0

F3 - Tacho Display F3

04 0

SZ – Dragging Value

05 1 0 0 0

P1 - Limit Value 1

06 2 0 0 0

P2 - Limit Value 2

10 - - - - - -

Separating

Line

11 S t a t 0

F1 - Status for Tacho Display F1

12 S t a t 0

F2 - Status for Tacho Display F2

13 S t a t 0

F3 - Status for Tacho Display F3

14 S t a t 0

SZ - Status for Dragging Value

15 S t a t 0

P1 - Status for Limit Value 1

16 S t a t 0

P2 - Status for Limit Value 2

20 - - - - - -

Separating

Line

21 2 1 0

Calculating

Function

22 2 2 0

Inversion of Calculating Function

23 2 3 0

Count Mode Tacho 1

24 2 4 0

Input

Logic

25 2 5 b F 1

Evaluation Tacho F1

1.0 0 0 0

26 2 6 b F 2

Evaluation Tacho F2

1.0 0 0 0

27 2 7 b F 3

Factor for Calculating Function F3

1.0 0 0 0

28 2 8 1

Update-Time

F1,F2,F3

29 2 9 0

Time-out

F1,F2,F3

30 3 0 0

Time Unit Tacho F1

31 3 1 0

Time Unit Tacho F2

32 3 2 0

Assignment Dragging Value

33 3 3 0

Assignment Digital Output 1

34 3 4 0

Assignment Digital Output 2

35 3 5 0

Output Logic of Digital Outputs

36 3 6 0

Decimal Point F1

37 3 7 0

Decimal Point F2

38 3 8 0

Decimal Point F3

39 3 9 0

Selection Basic Display

40 4 0 C o d

Code

0

41 4 1 0

Assignment Function Key

42 4 2 0

Output Reaction Lower Limit Value

51 5 1 0

Baud

rate

52 5 2 0

Parity

53 5 3 0

Stop

Bits

54 5 4 0

Address

61 6 1 0

Analog Output Assignment

62 6 2 0

Offset for Analog Output

63 6 3 u A

Lower Analog Value

0

64 6 4 o A

Upper Analog Value

4 0 9 5

65 - - - - - -

Separating

Line

Advertising