9. Programming plan

line 11-16 status for lines 1-6

0 * Alter parameter
1

Lock of delete resp.enter

2

Skip parameter

line 21

Calcuating functions

0 * Relation tacho F1 : tacho F2
1

difference tacho F1 - tacho F2

2

stretching / compression

3

Flow time (length)

4

Time measurement - Start/Stopp

5

Time measurement – period

6

Time measurement – pulse duration

7

Pulse rate measurement

line 22

Inversion of calculating function

0 * Calculating function as above
1

inverted F1->F2 F2->F1

line 23

Count mode tacho for F1 and F2

0 * F1 Track A with Up/Down F2 40 kHz
1

F1 Track A 90° B F2 40 kHz

2

F1 Track A with Up/Down F2 25 Hz

3

F1 Track A 90° B F2 25 Hz

line 24

Input logic (for F1 and F2)

0 * PNP Trigger level approx. 11V
1

NPN Trigger level approx. 11V

2

PNP Trigger level approx. 5V

3

NPN Trigger level approx. 5V

4

PNP Trigger level approx. 2,5V

5

NPN Trigger level approx. 2,5V

line 25

Evaluation tacho F1

0.0001

Min.

1.0000 * Default
9999.99

Max.

line 26

Evaluation tacho F2

0.0001

Min.

1.0000 * Default
9999.99

Max.

line 27

Factor for calculation function F3

0.0001

Min.

1.0000 * Default
9999.99

Max.

line 28

minimum update time for F1-F3

0

Maximum update time (approx. 0,5s)

1 * 1 second
2

2 Seconds

3

3 Seconds

4

5 Seconds

5

10 Seconds

6

20 Seconds

7

30 Seconds

8

60 Seconds

line 29

Time out for F1-F3

0 * 1 second

(0,1S)

1

2 Seconds

(0,2s)

2

3 Seconds

(0,3s)

3

5 Seconds

(0,5s)

4

10 Seconds

(1s)

5

20 Seconds

(2s)

6

30 Seconds

(3s)

7

60 Seconds

(6s)

8

Time-out function out of order

(8s)

9

as 8 but store

(10s)

line 30

Time unit tacho F1

0 * 1/min
1

1/s

2

1/h

line 31

Time unit tacho F2

0 * 1/min
1

1/s

2

1/h



line 32

Assignment of dragging value

0 * F1
1

F2

2

F3

line 33

Assignment output 1

0 * Upper Limit value tacho F1
1

Lower Limit value tacho F1

2

Upper Limit value tacho F2

3

Lower Limit value tacho F2

4

Upper Limit value calculating function F3

5

Lower Limit value calculating function F3

line 34

Assignment output 2

0 * Upper Limit value tacho F1
1

Lower Limit value tacho F1

2

Upper Limit value tacho F2

3

Lower Limit value tacho F2

4

Upper Limit value calculating function F3

5

Lower Limit value calculating function F3

line 35

Output logic for digital output

0 * Both outputs as normally closed
1

Out 1 open, Out 2 closed

2

Out 1 closed, Out 2 open

3

Both outputs as normally open

line 36

Decimal point for tacho F1

0 * No decimal point
1

00000.0

2

0000.00

3

000.000

line 37

Decimal point for tacho F2

0 * No decimal point
1

00000.0

2

0000.00

3

000.000

line 38

Decimal point for calculating function F3

Calc. func. 0-2,7

Calc.func. 3-6

0 * No decimal point

59.59.99 min

1

00000.0

99.59.59 h

2

0000.00

"

3

000.000

"

line 39

Basic display selection

0 * No switchover to basic display
1

F1

2

F2

3

F3

4

SZ

5

P1

6

P2

line 40

Code

0000 * Code not active
:

9999

line 41

Function key assignment

0 * Function key not assigned
:

6

Maximum value (line 6)

line 42

Output reaction of lower limit value

1 * with contact lock
0

W/o contact lock

line 51

Baudrate

0 * 4800 Baud
1

2400 Baud

2

1200 Baud

3

600 Baud

line 52

Parity

0 * Even Parity
1

Odd Parity

2

No Parity



Line 53

Stop bits

0 * 1 Stop bit
1

2 Stop bits

Line 54

Device address

00 * Minimum value
:

99

Maximum value