Fortsetzung – Fluid Components International ST50 Benutzerhandbuch
Seite 20

FLUID COMPONENTS INTERNATIONAL LLC
ST50 MASS FLOW
This page is subject to proprietary rights statement on last page
20
Doc. No. 06EN303367 Rev. Cx
Tabelle 6. ST50 Liste der CLI Befehle,
Fortsetzung
Command Line Password: 357
COMMAND
COMMAND
MNEMONIC
FUNCTION
K[1-4]
R/W
K Factors
Float
L0
R/W
Line Size0
Float
L1
R/W
Line Size1
Float
M N
R/W
Minflow
Float
M X
R/W
Maxflow
Float
OM
R/W
Outmode
Integer
PF
R/W
Pulse Factor
Float
PL
R/W
Pulse Out
Integer
PS
R/W
Pulse Sample Period
Float
PW
R/W
Pulse W idth
Float
P0
R/W
Switch Point0
Integer
P1
R/W
Switch Point1
Integer
RO
R/W
RollOver Cntr
Long
RR
R
Reference R
Float
RS
R/W
RefR Slope
Float
RF
R/W
RefR Offs et
Float
SF
R
SFPS Flow
Float
SN
R/W
Serial Number
String (16 chars max.)
SO
R/W
Shop Order Number
String (16 chars max.)
S0
R/W
SpanDA C0 for 4-20mA #1
Integer
S3
R/W
SpanDA C1 for 4-20mA #2
Integer
S2
W
Save FA CTORY
N/A
TC
R
TCdeltar
Float
TD
R/W
Tcs lp
Float
TF
R/W
Totalizer OFF/ON Flag
Integer
TM
R/W
Cmintemp
Float
TP
R/W
Totalizer Temperature Flag
Integer
TT
R/W
Totalizer Value
Float
TX
R/W
Cmaxtemp
Float
TZ
R
Temperature
Float
T0
R/W
Tcs lp0
Float
T2
R/W
Tcs lp2
Float
T3
R/W
TSpanDA C0 for 4-20mA #1
Integer
T7
R/W
TSpanDA C1 for 4-20mA #2
Integer
T5
R/W
TZeroDA C0 for 4-20mA #1
Integer
T8
R/W
TZeroDA C1 for 4-20mA #2
Integer
UF
R
Us er Flow
Float
UK
R
Us er FlowK
Float
UN
R/W
Us er Name
String (16 chars max.)
VN
R
Vers ion Number
String (16 chars max.)
XX
R/W
Tes t Flow Rate (SFPS)
Float
XY
W
Delete Tes t Flow Rate
Float
Z0
R/W
ZeroDAC0 for 4-20mA #1
Integer
Z2
R/W
ZeroDAC1 for 4-20mA #2
Integer
COMMAND DESCRIPTION
DATA TYPE