4 class 05 – devicenet connection object, 5 class 40 (28hex) – motor data object, 5 class 40 (28 – NORD Drivesystems BU0080 Benutzerhandbuch
Seite 40: Motor data object

NORDAC DeviceNet Handbuch
40
BU 0080 DE
6.5.4
Class 05 – DeviceNet Connection Object
In diesem Objekt können die Einstellungen für jede aktive Verbindung ausgelesen werden:
Instanz 1: Expl.Message
Instanz 2: Polling
Instanz 3: Bit-Strobe
Instanz 4: COS/Cyclic
Inst Attr.
Beschreibung
Typ
Access
1 State
USINT
Get
2 Instance
Type
USINT
Get
3 transportClass_trigger
BYTE
Get
4 produced_connection_id
UINT
Get
5 consumed_connection_id
UINT
Get
6 initial_comm_characteristic
BYTE
Get
7 produced_connection_size
UINT
Get
8 consumed_connection_size
UINT
Get
9 expected_packet_rate
UINT
Get/Set
12 watchdog_timeout_action
USINT
Get
13 produced_con_path_length
UINT
Get
14 produced_connection_path EPATH
Get
15 consumed_con_path_length
UINT
Get
16 consumed_connection_path EPATH
Get
1-4
17 produced_inhibit_time
UINT
Get
6.5.5
Class 40 (28
hex
) – Motor Data Object
Über das Motor Data Object können Motorspezifische Daten eingestellt bzw. gelesen werden. Dieses Objekt
ist nur gültig, wenn das AC-Profil eingeschaltet ist (s.o.)!
Inst Attr.
Beschreibung
Typ
Access
3 Motor
Type
USINT
Get
6 Stator Strom [0,1A]
UINT
Get
7 Nennspannung
[V]
UINT
Get/Set
8 Nennleistung
[W]
UDINT
Get/Set
9 Nennfrequenz
UINT
Get/Set
1
12 Polzahl
UINT
Get