Technical specifications – Festo Линейный привод с датчиком перемещения DGPIL Benutzerhandbuch

Seite 17

Advertising
background image

Technical specifications

Pneumatic/Mechanical

Type

DGPI(L)-
25-...-B

DGPI(L)-
32-...-B

DGPI(L)-
40-...-B

Assembly position

As required

Design

Double-acting pneumatic cylinder without piston with fixed piston-slide connection

and integrated measuring system

Operating pressure range

2 – 8 bar

1.5 – 8 bar

Permitted temperature range

–10

o

C bis + 60

o

C

Medium

Filtered compressed air, lubricated

Theoretical piston force at 6 bar*)

295 N

483 N

754 N

Slide weight force

DGPI

0.18

0.314

0.551

DGPIL

0.603

0.892

1.699

Max. leakage when new at 6 bar

10 l/h

End position cushioning

Pneumatic adjustable

Cushioning length *)

18 mm

20 mm

30 mm

Permitted work load components vertical to
cylinder axis *)

dependent on type, speed and loading;

must be calculated by means of catalogue

Perm. static slide torques *)

Materials

Cylinder profile, End cover, Driver: AL anodised; Seals, Sealing tape: PU, NBR;

Guide band, Wiper, Deflector: POM; Adhesives: Loctite 662/684

Guide rail: St (with anti friction guideway)

*) Please note the installation instructions (part no. 357688) with the SPC 100.

Fig.21

9712a

D/GB 17

Advertising