EUCHNER SN01 Single Limit Switches Benutzerhandbuch

Seite 6

Advertising
background image

Operating Instructions Precision Single Limit Switches N01/NB01/SN01

Figure 6: Dimension drawing/connection diagram N01.550C1526 with plug connector M12

(4-pin)

≥ 45

35

15

Inserted

Angled plug connector

+

GN

YE

WH

BU

BK

BN

2

3

4

1

C

NO

NC

∅ 6

9,

5

11

13,

5

27

30°

ma

x.

M16x1,5

50

22

45

∅ 8

∅ 4,3

25

4,

2

12,

5

±0,

3

Operating

point

F

ree position

Plunger type
depending on
switch type

Dog

Figure 8: Dimension drawing SN01.. with cable entry

Safety venting
valve

Figure 4: Dimension drawing/connection diagram N01.550X... with connection cable

(PUR cable, 4x0.5 mm²)

20

Cable glands
M12x1.5

GNYE

BU

BK

BN

C

NO

NC

For version C2043
silicone cable

Figure 9: Dimension drawing/connection diagram SN01.558X... with connection

cable (PUR cable, 5x0.5 mm²)

20

Cable gland
M16x1.5

BN

2

1

21

22

BK

4

14

BU

3

GNYE

13

BK

Figure 5: Dimension drawing/connection diagram N01.550SVM5 with plug connector M12

(SVM5, 5-pin)

45

°

24

26,5

31

Angled plug connector, adjustable to a
max. of 270°.
Standard position:
Plug connector downwards.

Guide lug aligned

WH

BU

BK

BN

2

3

4

1

C

NO

NC

GNYE

Figure 10: Dimension drawing/connection diagram SN01.558SVM5 with plug connector

M12 (SVM5, 5-pin)

20

45

°

26,5

31

Right-angle plug connector, cable outlet
adjustable, max. 270°.
Standard position:
cable outlet downward.

Guide lug aligned

WH

BN

2

1

21

22

BK

4

14

BU

3

GNYE

13

Figure 7: Dimension drawing N01...MC2018/NB01.620-MC2018 with special cable

gland

Figure 11: Switching elements, wiring diagrams and terminal assignment N01.../NB01.../

SN01... with cable entry

Switching element

Wiring diagram

Terminal assignment

ES550

ES593

ES553

ES556

ES562

ES572

ES620

ES558

ES588

1

4 (NO)

2 (NC)

(C)

1 (NC)

2 (NC)

4 (NO)

3 (NO)

1

2 (NC)

(C)

4

2

1

3

2

4

1

1

2

4

2

4

1

2

4

1

1

2

4

Figure 3: Dimension drawing N01.../NB01... with cable entry

20

∅ 6

25

∅ 4,3

∅ 8

9,

5

11

27

40

a

M12x1,5

4,

2

30°

ma

x.

13,5

12,

5

-0

,5

±0,

3

l

Operating

point

F

ree position

Plunger type
depending on
switch type

On the switching element
ES588 the safe positive
opening function is
dependent on observance of

the dimension

11

-0,5

.

Dog

Safety venting
valve

2

M12 x 1.5

For cable diameter 4.5 ...
6.5 mm

N01...MC2018

NB01.620-MC2018

6

M12 x 1.5

For cable diameter 4.5 ...
6.5 mm

Type

Dimension

a Dimension l

[mm]

[mm]

N01...

2

40

NB01.556-M

2

44

NB01.588-M

2

58

NB01.620-M

6

48.5

Advertising