EUCHNER SN01 Single Limit Switches Benutzerhandbuch
Seite 6
Operating Instructions Precision Single Limit Switches N01/NB01/SN01
Figure 6: Dimension drawing/connection diagram N01.550C1526 with plug connector M12
(4-pin)
≥ 45
35
15
Inserted
Angled plug connector
+
GN
YE
WH
BU
BK
BN
2
3
4
1
C
NO
NC
∅ 6
9,
5
11
13,
5
27
30°
ma
x.
M16x1,5
50
22
45
∅ 8
∅ 4,3
25
4,
2
12,
5
±0,
3
Operating
point
F
ree position
Plunger type
depending on
switch type
Dog
Figure 8: Dimension drawing SN01.. with cable entry
Safety venting
valve
Figure 4: Dimension drawing/connection diagram N01.550X... with connection cable
(PUR cable, 4x0.5 mm²)
20
Cable glands
M12x1.5
GNYE
BU
BK
BN
C
NO
NC
For version C2043
silicone cable
Figure 9: Dimension drawing/connection diagram SN01.558X... with connection
cable (PUR cable, 5x0.5 mm²)
20
Cable gland
M16x1.5
BN
2
1
21
22
BK
4
14
BU
3
GNYE
13
BK
Figure 5: Dimension drawing/connection diagram N01.550SVM5 with plug connector M12
(SVM5, 5-pin)
45
°
24
26,5
31
Angled plug connector, adjustable to a
max. of 270°.
Standard position:
Plug connector downwards.
Guide lug aligned
WH
BU
BK
BN
2
3
4
1
C
NO
NC
GNYE
Figure 10: Dimension drawing/connection diagram SN01.558SVM5 with plug connector
M12 (SVM5, 5-pin)
20
45
°
26,5
31
Right-angle plug connector, cable outlet
adjustable, max. 270°.
Standard position:
cable outlet downward.
Guide lug aligned
WH
BN
2
1
21
22
BK
4
14
BU
3
GNYE
13
Figure 7: Dimension drawing N01...MC2018/NB01.620-MC2018 with special cable
gland
Figure 11: Switching elements, wiring diagrams and terminal assignment N01.../NB01.../
SN01... with cable entry
Switching element
Wiring diagram
Terminal assignment
ES550
ES593
ES553
ES556
ES562
ES572
ES620
ES558
ES588
1
4 (NO)
2 (NC)
(C)
1 (NC)
2 (NC)
4 (NO)
3 (NO)
1
2 (NC)
(C)
4
2
1
3
2
4
1
1
2
4
2
4
1
2
4
1
1
2
4
Figure 3: Dimension drawing N01.../NB01... with cable entry
20
∅ 6
25
∅ 4,3
∅ 8
9,
5
11
27
40
a
M12x1,5
4,
2
30°
ma
x.
13,5
12,
5
-0
,5
±0,
3
l
Operating
point
F
ree position
Plunger type
depending on
switch type
On the switching element
ES588 the safe positive
opening function is
dependent on observance of
the dimension
11
-0,5
.
Dog
Safety venting
valve
2
M12 x 1.5
For cable diameter 4.5 ...
6.5 mm
N01...MC2018
NB01.620-MC2018
6
M12 x 1.5
For cable diameter 4.5 ...
6.5 mm
Type
Dimension
a Dimension l
[mm]
[mm]
N01...
2
40
NB01.556-M
2
44
NB01.588-M
2
58
NB01.620-M
6
48.5