Operating instructions safety switches tp...as, Status table – EUCHNER TPxxxAS2 Benutzerhandbuch
Seite 6

Operating Instructions Safety Switches TP...AS
2
Figure 4: Min. door radii
Actuator type
Door radius min. [mm]
Actuator P-G...
1,000
Actuator P-W...
1,000
HINGED ACTUATOR P-OU...
90
HINGED ACTUATOR P-LR...
100
Hinged actuator P-OU / P-OUN
12
26
20
35
28
+2
R > 90
Hinged actuator P-LR / P-LRN
R > 10
0
Figure 3: Dimension drawings
35
3,
5
30
40
144
192
31
22
16
16
43
8,5
3,5
h
42
14
v
M20x1,
5 (
2
x)
GN RD
Power Fault
For M5 > 35 mm
ISO 1207 (DIN84)
ISO 4762
(DIN 912)
M = 1.5 Nm
Mechanical
release
M = 0.5 Nm
Locking screw
M = 0.6 Nm
Status table
Programming
State
D0, D1
D2, D3
Monitor diagnosis
Safety guard closed,
Code sequence
Green
guard locking active or not active.
2-channel
Intermediate state during opening or closing
dependent
of the safety guard.
Half-seq.
00
During opening: yellow flashing
Synchronization time
Switch S1 (internal) open
During closing: red
3 s
Intermediate state during opening or closing
After expiration of the synchronization time:
of the safety guard.
00
Half-seq.
yellow flashing
Switch S2 (internal) open
Safety guard open
00
00
Red
Address 0 or communication disrupted
–
Gray