Operating Instructions Safety Switches STP-TW...AS

1

0,3

v

h

h

v

<72>

171

27

30

<42>

GN

RD

Power Fault

20

4

4

16

0,3

<74>

<80>

144

<42>

30

4

228

14

16

20

Figure 4: Dimension drawing STP-TW...AS

∅ 5.3 (2x)
for M5x35 mm
ISO 1207/ISO 4762

Mechanical
release

Locking screw

Necessary minimum travel + permissible overtravel

Approach direction

Actuator

S standard

Horizontal (h)

24.5 + 5

Vertical (v)

24.5 + 5

∅ 5.3 (2x)
for M5x35 mm
ISO 1207/ISO 4762

EC declaration of conformity

The manufacturer named below herewith declares that
the product fulfills the provisions of the directive(s)
listed below and that the related standards have been
applied.
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen, Germany
Directives applied:

f

Machinery directive 2006/42/EC

Standards applied:

f

EN 60947-5-1:2004 + Cor.:2005 + A1:2009

f

EN 1088:1995+A2:2008

Leinfelden, July 2010
Dipl.-Ing. Michael Euchner
Director
Duc Binh Nguyen
Authorized representative empowered to draw up
documentation
The signed EC declaration of conformity is included
with the product.

Technical data

Parameters

Value

Housing material

Reinforced
thermoplastic

Deg. of prot. acc. to IEC 529 IP 67, mating connector plugged
Mechanical life

1x10

6

operating cycles

Ambient temperature

-20 ... +55°C

Installation position

Any

Approach speed, max.

20 m/min

Actuating force

35 N

Extraction force

30 N (not locked)

Retention force

20 N

Locking force F

max

2,500 N

Locking force F

Zh

according to GS-ET-19
Weight

Approx. 0.6 kg

Switching principle SK, ÜK

Positively driven, slow-action
switching contact

EMC protection requirements Acc. to EN 50295 (AS-Interface

standard) and IEC 62026

Guard solenoid
Solenoid operating voltage

DC 24 V +10%/-15%

8 W

(auxiliary power on black

Power supply unit with safe isolation

AS-Interface line)

(IEC 60742, PELV)

Solenoid operating current

300 mA

Duty cycle

100%

Connection

M12 plug connector

Minimum travel and overtravel
Approach direction

Actuator

S

Actuator

L for

Standard

Insertion funnel

horizontal (h) + vertical (v)

24.5 + 5

28.5 + 5

AS-Interface data acc. to

EA code: 7

AS-Interface specification 2.1 ID code: B
Operating voltage AS-Interface DC 22.5 ... 31.6 V
Total current consumption, max. 45 mA
Valid AS-Interface addresses

1 - 31

AS-Interface inputs

Acc. to AS-Interface Safety at Work

Door monitoring contact SK

D0, D1

Solenoid monitoring contact ÜK D2, D3
AS-Interface outputs
D0

Guard locking solenoid,
1 = solenoid energized

D1

Red LED, 1 = LED on

D2

Green LED, 1 = LED on

AS-Interface LED Power

Green, AS-Interface voltage present

AS-Interface LED Fault

Red, offline phase or address 0

Reliability values according to EN ISO 13849-1
B

10d

4.5 x 10

6

(F

Zh

=

F

max

) = 2000 N

1,3

Do not use these
mounting holes!

Advertising