Operating instructions safety switches stp-tw...as – EUCHNER STP-TWxxxAS1 Benutzerhandbuch
Seite 8

Operating Instructions Safety Switches STP-TW...AS
1
EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 Fax +49/711/75 33 16 www.euchner.de [email protected]
Figure 5: Min. door radii
Actuator type
Door radius min. [mm]
Actuator S-G...
300
Actuator S-W...
300
HINGED ACTUATOR S-OU...
200
HINGED ACTUATOR S-LR...
200
Hinged actuator S-OU-LN
for insertion funnel
Hinged actuator S-LR-LN
for insertion funnel
16
30
R >
200
35,5
4
28,5 +5
20
R>200
Hinged actuator S-OU-SN
Hinged actuator S-LR-SN
24,5 +5
12
26
35,5
R >
20
200
R>200
Status table
Programming
State
D0, D1
D2, D3
Monitor diagnosis
Safety guard closed, guard locking active
Code sequence
Green
Guard locking open
Half-seq.
00
Yellow flashing
2-channel
Invalid state
00
Half-seq.
Red flashing
conditionally
(safety guard open, guard locking active)
(monitoring of the invalid state)
dependent
Safety guard open
00
00
Red
Address 0 or communication disrupted
–
Gray
Safety guard closed, guard locking active
Code sequence
Green
Guard locking open
Half-seq.
00
Red
2-channel
Invalid state
00
Half-seq.
Red
independent
(safety guard open, guard locking active)
(monitoring of the invalid state)
Safety guard open
00
00
Red
Address 0 or communication disrupted
–
Gray
Green if safety guard was previously open
Safety guard closed, guard locking active
Code sequence
or yellow flashing after startup,
if only guard locking was open.
2-channel
Yellow flashing,
dependent
Guard locking open
Half-seq.
00
if guard locking was previously closed.
Synchronization time
Red if safety guard was previously open.
infinite
∞
∞
∞
∞
∞
Invalid state
Yellow flashing,
(safety guard open, guard locking active)
00
Half-seq.
if safety guard was previously closed.
Red if safety guard was previously open.
Safety guard open
00
00
Red
Address 0 or communication disrupted
–
Gray