Notes on using these connection and operating instructions

These connection and operating instructions contain information regarding the proper
and effective use of the Safety Basic Monitor.

See the manuals "SBM Safety Basic Monitor" and "ASIMON configuration software"
for detailed information.

Safety precautions and warnings are designated by the

symbol.

EUCHNER GmbH + Co. KG is not liable for damage resulting from improper use of
its equipment. Familiarity with these instructions constitutes part of the knowledge re-
quired for proper use.

© Reprint and reproduction, in whole or in part, only with the explicit permission of:

EUCHNER GmbH + Co. KG

Kohlhammerstraße 16

*

D-70771 Leinfelden-Echterdingen

Tel. +49(0)711/7597-0

Fax +49(0)711/753316

Internet: http://www.euchner.de

This short description of the connection and operating instruction is a part of the scope
of delivery.

Spezial features:

2 (4) local electronical safe outputs.

Up to 8 / 4 local safe inputs. Optionally the safe inputs will be used as well as
standard inputs and signal outputs.

Safe AS-i outputs are supported (max. 8 independent AS-i outputs multiple safe
AS-i outputs possible via a single address).

Chip card for storage of configuration data.

Protection category IP20.

Technical data

Safety characteristics

1.)

Probability of a dangerous loss per hour.

Maintenance

The proper function of the safety monitor within the system to be secured, i.e. the safe
shutdown following the triggering of an assigned safety related sensor or switch, is to
be checked at least once a year by the safety officer.

Assembly

The Safety Basic Monitor is assembled on 35 mm standard rails in accordance with
DIN EN 50 022.

For assembling, position the device on the upper edge of the standard rail and then
snap it onto the bottom edge.

Connections

Derating by 24 V auxiliary power

Translation of the original operating instructions

SBM Safety Basic Monitor

without Power Supply Decoupling Unit

SBM-11-S08

SBM Safety Basic Monitor

with Power Supply Decoupling Unit

SBM-11-N08

Specified normal operation of the safety monitor:

The Safety Monitor has been designed as a disconnecting protective de-

vice for safeguarding danger zones on power-driven work equipment.

The safe outputs bring a machine into a safe state.

Error states of the remote outputs used in the safe configuration can be

eliminated by starting and stopping the monitor.

Configuration

The configuration of the device is done using the ASIMON 3 G2 soft-

ware and the AS-i Control Tools. Connect the device with the PC using

the micro-USB interface.

For connecting and commissioning the safety monitor, comprehension

of the connection and operating instructions as well as the operating in-

structions of ASIMON configuration and diagnostic software is neces-

sary.

Person protection function:

The Safety Monitor fulfills a person protection function. Improper instal-

lation impairs the function! The manufacturer of the machine/plant in

which the safety related system is used is responsible for the correct and

safe total function of every individual safety component! Depending on

the choice of safety devices used, the safety system as a whole may

also be assigned to a lower safety category!

Id.-N

o

.:

114015 - Issu

e date:

2011-10-17

Su

bj

ec

t to ch

an

ge

w

ith

ou

t pri

or no

tic

e

02102800000000001

SBM-11-S08

113831

SBM Safety Basic Monitor

Euchner GmbH+Co.KG YoC: 2011
Kohlhammerstr. 16 70771 Leinfelden

without Power Supply Decoupling Unit

Version NO.:
Safety Version:

FA.0001

13829
V4.2

02102800000000001

SBM-11-N08

113830

SBM Safety Basic Monitor

Euchner GmbH+Co.KG YoC: 2011
Kohlhammerstr. 16 70771 Leinfelden

with Power Supply Decoupling Unit

Version NO.:
Safety Version:

FA.0001

13828
V4.2

Connection

COMBICON clamp

Respond delay

< 40ms

AS-i Master

integrated

Interface

USB, chip card slot

AS-i voltage

18 ... 31,6V

Max. AS-i current consumption

200 mA

AUX voltage

20 ... 30V (PELV)

Max. AUX current consumption

4A max.

Supply voltage inputs

of AUX (24V auxiliary power)

Network connection between the

safe input terminals

max. resistance 150

8 / 4 safe inputs cat. 4

or

8 standard in -and outputs

switching current statical 4mA at 24V, dynamic

30mA at 24V (T=100s)

2 (4) output switching elements

semiconductor outputs (output circuits 1 and 2)

max. contact load: 700mA DC-13 at 24V

Supply voltage outputs

of AUX (24V auxiliary power)

Max. output current signal outputs

10mA each output

Max. output current for OSSD sup-

ply

1,4A (S71)

Test pulse

when output is switched on

minimal distance between 2 test pulses:

250ms, pulse length to 1ms

4x LEDs yellow (S1, S2, S3, S4)

state of input S1, S2, S3 and S4

4x LEDs yellow (S5, S6, S7, S8)

state of input S5, S6, S7 and S8

LED green/yellow/red (SM)

state of Safety Monitor

LED green/yellow/red (AS-i M)

state of AS-i Master

LED green/yellow/red (O1)

output 1 has switched

LED green/yellow/red(O2)

output 2 has switched

1 button

service

Voltage of insulation AS-i/AUX

500V

Operating temperature

0°C … +55°C

Storage temperature

-25°C … +85°C

Housing

DIN-rail mounting

Protection class DIN 60 529

IP20

Dimensions (L / W / H in mm)

99 / 22,5 / 114

Characteristics

Value

Standard

Safety category

4

EN 954-1

EN 13 849-1:2008

Performance Level (PL)

e

EN 13 849-1:2008

Safety Integrity Level (SIL)

3

IEC 61 508, EN 62 061

Service life (TM) [year]

20

EN 13 849-1:2008

Maximal power-on time (month)

12

IEC 61 508

PFD

9,58 x 10

-7

EN 62 061

PFH

D

1

5,08 x 10

-9

IEC 61 508, EN 62 061

Max. reaction time [ms]

IEC 61 508

AS-i input slave local output

40

local input local output

20

local input AS-i code sequence

26

AS-i input slave AS-i code sequence

45

If the option „augmented reliability“ is selected the response time can ex-

tend.

For this purpose, every safety related AS-i slave must be activated at

least once per year and the switching behavior must be inspected by

monitoring the output circuits of the safety monitor.

The maximum power-on time and total operating time depends on the

PFD value selected for the overall failure probability.

When the maximum power-on time has been reached (three, six or

twelve months), the safety system must be checked to ensure that it is

functioning correctly by prompting the shutdown function.

When the total operating time has been reached (20 years), the device

must be checked at the manufacturer's factory to ensure that it is func-

tioning correctly.

Have installation done professionally:

Electrical installation is to be performed by a trained expert. During in-

stallation, care must be taken that supply and signal cables and also the

AS-i bus cable are laid separately from high-voltage cables. In the

switch cabinet, it must be ensured that appropriate spark-quenching

equipment is used with contactors. Where drive motors and brakes are

used, attention must be paid to the installation instructions in the corre-

sponding operating instructions. Please note that the maximum cable

length of the AS-i bus cable is 100 m. Cables above that length require

the use of a suitable circuit extension.

It is essential to adhere to the prescribed fuse protection; this is the only

way of guaranteeing safe disconnection in the case of a fault.

Control and indicating elements, configuration

See <data sheet

> and <manual ASIMON configuration software>.

Micro USB

micro USB interface

SET

teach/service button

Chip Card

chip card

1.14

ext.out

semiconductor output 1

2.14

ext.out

semiconductor output 2

0V

ext.out

ground connection for semiconductor output

ASI+, ASI–

connection to the AS-i Bus

AUX+

ext.in

, AUX-

ext.in

connection to ext. 24 V

DC

PELV

Connection

2-channel

direction

S11, S22

input 1

output

S12, S21

input

S31, S42

input 2

output

S32, S41

input

S51, S62

input 3

output

S52, S61

input

S71, S82

input 4

output

S72, S81

input

0,8 Nm
7 LB.IN

5 ... 6 mm / PZ2

10

10

AWG

2 x 24 ...12

2 x (0,5 ... 1,5) mm

2

2 x (0,5 ... 1,5) mm

2

I

AUX, max [A]

1

2

3

3,5

40

55

Tamb [°C]

LEDs

Status

Signal // Description

S1, S2, S3, S4, S5, S6,
S7, S8

(yellow)

contact (S1 … S8) open

1 Hz cross connection

contact (S1 … S8) closed

SM

a

a.

’yellow’ has higher priority than ’red’ and ’green’ and will displayed preferentially.

AS-i voltage not OK

(green)

1 Hz ’protective mode’ and ASIMON active

’protective mode’ active

(red)

1 Hz ’configuration mode’ and ASIMON active

’configuration mode’ active

2 Hz

at least 1 device in state ’red flashing’ or ’yellow flashing’

(yellow)

2 Hz

1 Hz service button, state: ’teach error’

service button, state: ’ready’

AS-i M

b

b.

If ’config-error’ and ’peripheral fault’ occur simultaneously, only ’config-error’ is displayed.

off-line, monitor mode

(red)

1 Hz peripheral fault, without ’Config-Error’

’Config-Error’, auto addressing not possible

1 Hz

’Config-Error’, auto addressing possible

(green)

2 Hz

Master: ’protective mode’ , no error

1 Hz Master: ’configuration mode’, no error

O1, O2

c

c.

’red’ has higher priority than ’yellow’.

output (O1, O2) off

(yellow)

1 Hz restart inhibit

8 Hz correctable error state

output (O1, O2) on

(red)

no auxiliary voltage

SM, AS-i M, O1, O2

1 Hz

competing master active

1.14

ext. out

ASI

+

0

V

ext. out

ASI

2.14

ext. out

AUX+

ext. in

0

V

ext. out

AUX–
ext. in

S

71 S

72 S

81 S

82

S

42 S

41 S

32 S

31

S

62 S

61 S

52 S

51

S

22 S

21 S

12 S

11

K2

K1

L1 L2 L3

Motor

AUX+

ext. in

S32

1.14

ext.out

0V

ext.out

+

ASI

+ –

AUX

(24 V

DC

)

(PELV)