EUCHNER SBM-11-N08 Benutzerhandbuch
Seite 3

Notes on using these connection and operating instructions
These connection and operating instructions contain information regarding the proper
and effective use of the Safety Basic Monitor.
See the manuals "SBM Safety Basic Monitor" and "ASIMON configuration software"
for detailed information.
Safety precautions and warnings are designated by the
symbol.
EUCHNER GmbH + Co. KG is not liable for damage resulting from improper use of
its equipment. Familiarity with these instructions constitutes part of the knowledge re-
quired for proper use.
© Reprint and reproduction, in whole or in part, only with the explicit permission of:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
*
D-70771 Leinfelden-Echterdingen
Tel. +49(0)711/7597-0
Fax +49(0)711/753316
Internet: http://www.euchner.de
This short description of the connection and operating instruction is a part of the scope
of delivery.
Spezial features:
•
2 (4) local electronical safe outputs.
•
Up to 8 / 4 local safe inputs. Optionally the safe inputs will be used as well as
standard inputs and signal outputs.
•
Safe AS-i outputs are supported (max. 8 independent AS-i outputs multiple safe
AS-i outputs possible via a single address).
•
Chip card for storage of configuration data.
•
Protection category IP20.
Technical data
Safety characteristics
1.)
Probability of a dangerous loss per hour.
Maintenance
The proper function of the safety monitor within the system to be secured, i.e. the safe
shutdown following the triggering of an assigned safety related sensor or switch, is to
be checked at least once a year by the safety officer.
Assembly
The Safety Basic Monitor is assembled on 35 mm standard rails in accordance with
DIN EN 50 022.
For assembling, position the device on the upper edge of the standard rail and then
snap it onto the bottom edge.
Connections
Derating by 24 V auxiliary power
Translation of the original operating instructions
SBM Safety Basic Monitor
without Power Supply Decoupling Unit
SBM-11-S08
SBM Safety Basic Monitor
with Power Supply Decoupling Unit
SBM-11-N08
Specified normal operation of the safety monitor:
The Safety Monitor has been designed as a disconnecting protective de-
vice for safeguarding danger zones on power-driven work equipment.
The safe outputs bring a machine into a safe state.
Error states of the remote outputs used in the safe configuration can be
eliminated by starting and stopping the monitor.
Configuration
The configuration of the device is done using the ASIMON 3 G2 soft-
ware and the AS-i Control Tools. Connect the device with the PC using
the micro-USB interface.
For connecting and commissioning the safety monitor, comprehension
of the connection and operating instructions as well as the operating in-
structions of ASIMON configuration and diagnostic software is neces-
sary.
Person protection function:
The Safety Monitor fulfills a person protection function. Improper instal-
lation impairs the function! The manufacturer of the machine/plant in
which the safety related system is used is responsible for the correct and
safe total function of every individual safety component! Depending on
the choice of safety devices used, the safety system as a whole may
also be assigned to a lower safety category!
Id.-N
o
.:
114015 - Issu
e date:
2011-10-17
Su
bj
ec
t to ch
an
ge
w
ith
ou
t pri
or no
tic
e
02102800000000001
SBM-11-S08
113831
SBM Safety Basic Monitor
Euchner GmbH+Co.KG YoC: 2011
Kohlhammerstr. 16 70771 Leinfelden
without Power Supply Decoupling Unit
Version NO.:
Safety Version:
FA.0001
13829
V4.2
02102800000000001
SBM-11-N08
113830
SBM Safety Basic Monitor
Euchner GmbH+Co.KG YoC: 2011
Kohlhammerstr. 16 70771 Leinfelden
with Power Supply Decoupling Unit
Version NO.:
Safety Version:
FA.0001
13828
V4.2
Connection
COMBICON clamp
Respond delay
< 40ms
AS-i Master
integrated
Interface
USB, chip card slot
AS-i voltage
18 ... 31,6V
Max. AS-i current consumption
200 mA
AUX voltage
20 ... 30V (PELV)
Max. AUX current consumption
4A max.
Supply voltage inputs
of AUX (24V auxiliary power)
Network connection between the
safe input terminals
max. resistance 150
8 / 4 safe inputs cat. 4
or
8 standard in -and outputs
switching current statical 4mA at 24V, dynamic
30mA at 24V (T=100s)
2 (4) output switching elements
semiconductor outputs (output circuits 1 and 2)
max. contact load: 700mA DC-13 at 24V
Supply voltage outputs
of AUX (24V auxiliary power)
Max. output current signal outputs
10mA each output
Max. output current for OSSD sup-
ply
1,4A (S71)
Test pulse
when output is switched on
minimal distance between 2 test pulses:
250ms, pulse length to 1ms
4x LEDs yellow (S1, S2, S3, S4)
state of input S1, S2, S3 and S4
4x LEDs yellow (S5, S6, S7, S8)
state of input S5, S6, S7 and S8
LED green/yellow/red (SM)
state of Safety Monitor
LED green/yellow/red (AS-i M)
state of AS-i Master
LED green/yellow/red (O1)
output 1 has switched
LED green/yellow/red(O2)
output 2 has switched
1 button
service
Voltage of insulation AS-i/AUX
500V
Operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Housing
DIN-rail mounting
Protection class DIN 60 529
IP20
Dimensions (L / W / H in mm)
99 / 22,5 / 114
Characteristics
Value
Standard
Safety category
4
EN 954-1
EN 13 849-1:2008
Performance Level (PL)
e
EN 13 849-1:2008
Safety Integrity Level (SIL)
3
IEC 61 508, EN 62 061
Service life (TM) [year]
20
EN 13 849-1:2008
Maximal power-on time (month)
12
IEC 61 508
PFD
9,58 x 10
-7
EN 62 061
PFH
D
1
5,08 x 10
-9
IEC 61 508, EN 62 061
Max. reaction time [ms]
IEC 61 508
AS-i input slave local output
40
local input local output
20
local input AS-i code sequence
26
AS-i input slave AS-i code sequence
45
If the option „augmented reliability“ is selected the response time can ex-
tend.
For this purpose, every safety related AS-i slave must be activated at
least once per year and the switching behavior must be inspected by
monitoring the output circuits of the safety monitor.
The maximum power-on time and total operating time depends on the
PFD value selected for the overall failure probability.
When the maximum power-on time has been reached (three, six or
twelve months), the safety system must be checked to ensure that it is
functioning correctly by prompting the shutdown function.
When the total operating time has been reached (20 years), the device
must be checked at the manufacturer's factory to ensure that it is func-
tioning correctly.
Have installation done professionally:
Electrical installation is to be performed by a trained expert. During in-
stallation, care must be taken that supply and signal cables and also the
AS-i bus cable are laid separately from high-voltage cables. In the
switch cabinet, it must be ensured that appropriate spark-quenching
equipment is used with contactors. Where drive motors and brakes are
used, attention must be paid to the installation instructions in the corre-
sponding operating instructions. Please note that the maximum cable
length of the AS-i bus cable is 100 m. Cables above that length require
the use of a suitable circuit extension.
It is essential to adhere to the prescribed fuse protection; this is the only
way of guaranteeing safe disconnection in the case of a fault.
Control and indicating elements, configuration
See <data sheet
> and <manual ASIMON configuration software>.
Micro USB
micro USB interface
SET
teach/service button
Chip Card
chip card
1.14
ext.out
semiconductor output 1
2.14
ext.out
semiconductor output 2
0V
ext.out
ground connection for semiconductor output
ASI+, ASI–
connection to the AS-i Bus
AUX+
ext.in
, AUX-
ext.in
connection to ext. 24 V
DC
PELV
Connection
2-channel
direction
S11, S22
input 1
output
S12, S21
input
S31, S42
input 2
output
S32, S41
input
S51, S62
input 3
output
S52, S61
input
S71, S82
input 4
output
S72, S81
input
0,8 Nm
7 LB.IN
5 ... 6 mm / PZ2
10
10
AWG
2 x 24 ...12
2 x (0,5 ... 1,5) mm
2
2 x (0,5 ... 1,5) mm
2
I
AUX, max [A]
1
2
3
3,5
40
55
Tamb [°C]
LEDs
Status
Signal // Description
S1, S2, S3, S4, S5, S6,
S7, S8
(yellow)
contact (S1 … S8) open
1 Hz cross connection
contact (S1 … S8) closed
SM
a
a.
’yellow’ has higher priority than ’red’ and ’green’ and will displayed preferentially.
AS-i voltage not OK
(green)
1 Hz ’protective mode’ and ASIMON active
’protective mode’ active
(red)
1 Hz ’configuration mode’ and ASIMON active
’configuration mode’ active
2 Hz
at least 1 device in state ’red flashing’ or ’yellow flashing’
(yellow)
2 Hz
1 Hz service button, state: ’teach error’
service button, state: ’ready’
AS-i M
b
b.
If ’config-error’ and ’peripheral fault’ occur simultaneously, only ’config-error’ is displayed.
off-line, monitor mode
(red)
1 Hz peripheral fault, without ’Config-Error’
’Config-Error’, auto addressing not possible
1 Hz
’Config-Error’, auto addressing possible
(green)
2 Hz
Master: ’protective mode’ , no error
1 Hz Master: ’configuration mode’, no error
O1, O2
c
c.
’red’ has higher priority than ’yellow’.
output (O1, O2) off
(yellow)
1 Hz restart inhibit
8 Hz correctable error state
output (O1, O2) on
(red)
no auxiliary voltage
SM, AS-i M, O1, O2
1 Hz
competing master active
1.14
ext. out
ASI
+
0
V
ext. out
ASI
–
2.14
ext. out
AUX+
ext. in
0
V
ext. out
AUX–
ext. in
S
71 S
72 S
81 S
82
S
42 S
41 S
32 S
31
S
62 S
61 S
52 S
51
S
22 S
21 S
12 S
11
K2
K1
L1 L2 L3
Motor
AUX+
ext. in
S32
1.14
ext.out
0V
ext.out
+
ASI
–
+ –
AUX
(24 V
DC
)
(PELV)