4 technical data, Measuring cir c uit monitoring – JUMO 707040 dTRANS T04 - 4-Wire Transmitter Operating Manual Benutzerhandbuch
Seite 68

32
4 Technical data
Measuring cir
c
uit monitoring
Underrang
e
:
- curr
ent outpu
t 4
—
20
mA
- curr
ent outpu
t 0
—
20
mA
- voltage outpu
t 0
—
10
V
falling to
≤
3.
6
m
A
< 0
m
A (-0.05
mA typical)
< 0
V
(-0.6
V
typical)
Overrange
- curr
ent outpu
t 4
—
20
mA
- curr
ent outpu
t 0
—
20
mA
- voltage outpu
t 0
—
10
V
rising to
>
21.6
m
A
—
<
28
mA (24
m
A typical)
rising to
>
21.6
m
A
—
<
28
mA (24
m
A typical)
rising to
>
11
V
—
<
14
V (12
V
typical)
Pr
obe short-cir
c
uit:
- curr
ent outpu
t 4
—
20
mA
- curr
ent outpu
t 0
—
20
mA
- voltage outpu
t 0
—
10
V
≥
1.5
m
A
—
≤
3.6
m
A (2
mA typica
l)
< 0
m
A (-0.05
mA typical)
< 0
V
(-0.6
V
typical)
Pr
obe and lead br
eak:
- curr
ent outpu
t 4
—
20
mA
- curr
ent outpu
t 0
—
20
mA
- voltage outpu
t 0
—
10
V
Signal is configu
rable.
positive signal:
>
21.6
m
A
—
<
28
mA (24
m
A typi
cal
)
negative signal:
≥
1.5
m
A
—
≤
3.6
m
A (2
mA typical)
positive signal:
>
21.6
m
A
—
<
28
mA (24
m
A typi
cal
)
negative signal: < 0
m
A (-0.05
m
A typical)
positive signal:
>
11
V
—
<
14
V (12
V
ty
pical)
negative signal: <
0V
(
-0
.6V
t
y
p
ic
a
l)