5 technical data, Technical data, Input for thermocouple – JUMO 707010 dTRANS T01 (T) HART - 2-Wire Transmitter Operating Manual Benutzerhandbuch
Seite 29

11
5 Technical data
Input for thermocouple
De
signation
R
ange limits
Ra
nge
A
c
c
ur
acy
1
Fe-Con
L
-200
to
+
900
°C
-200
to
+900
°C
0.5
°C typ.
Fe-Con
J
-210
to
+
1200
°C
-150
to
+1200
°C
0.5
°C typ.
Cu-Con
U
-200
to
+
600
°C
-200
to
+600
°C
0.5
°C typ.
Cu-Con T
-270
to
+
400
°C
-200
to
+400
°C
0.5°C
typ.
NiCr
-Ni K
-270
to
+
1372
°C
-140
to
+1372
°C
0.5
°C
typ.
NiCr
-Con E
-270
to
+1000
°C
-150
to
+1000
°C
0.5
°C
typ.
NiCrSi-NiSi N
-270
to
+
1300
°C
-100
to
+1300
°C
1
°C
typ.
Pt10Rh-Pt S
-50
to
+1768
°C
20
—
1768
°C
2°C
typ.
Pt13Rh-Pt
R
-50
to
+1768
°C
50
—
1768
°C
2
°C typ.
Pt30Rh-Pt6Rh
B
0
—
1820
°C
400
—
1820
°C
2
°C typ.
W3Re-W25Re
D
0
—
2495
°C
500
—
2495
°C
1
°C typ.
W5Re-W26Re
C
0
—
2320
°C
500
—
2320
°C
1
°C typ.
Shortest span
T
y
pe L, J,
U, T
, K, E, N: 50°C
T
y
pe S, R, B: 500°C
T
y
pe D, C: 500
°C
Cold junction
Pt100 inter
n
al
or exter
n
al cold jun
c
tion
(adjustable fr
om 0
to
8
0
°C)
Cold junction
accuracy
± 1
°C
Sampling rate
> 1 measur
ement per secon
d
Sensor curr
ent
350
nA
In
put fil
ter
1st or
de
r di
gi
tal fi
lter;
filter con
stant adjustable fr
om 0
to 100
sec
Special featur
es
can also
be pr
og
rammed in °F;
range limits ar
e f
reely pr
ogrammable;
input isolated fr
om output
1
T
h
e accur
a
cy r
e
fers to
the maximum range span.