5 technical data, Technical data, Input for thermocouple – JUMO 707010 dTRANS T01 (T) HART - 2-Wire Transmitter Operating Manual Benutzerhandbuch

Seite 29

Advertising
background image

11

5 Technical data

Input for thermocouple

De

signation

R

ange limits

Ra

nge

A

c

c

ur

acy

1

Fe-Con

L

-200

to

+

900

°C

-200

to

+900

°C

0.5

°C typ.

Fe-Con

J

-210

to

+

1200

°C

-150

to

+1200

°C

0.5

°C typ.

Cu-Con

U

-200

to

+

600

°C

-200

to

+600

°C

0.5

°C typ.

Cu-Con T

-270

to

+

400

°C

-200

to

+400

°C

0.5°C

typ.

NiCr

-Ni K

-270

to

+

1372

°C

-140

to

+1372

°C

0.5

°C

typ.

NiCr

-Con E

-270

to

+1000

°C

-150

to

+1000

°C

0.5

°C

typ.

NiCrSi-NiSi N

-270

to

+

1300

°C

-100

to

+1300

°C

1

°C

typ.

Pt10Rh-Pt S

-50

to

+1768

°C

20

1768

°C

2°C

typ.

Pt13Rh-Pt

R

-50

to

+1768

°C

50

1768

°C

2

°C typ.

Pt30Rh-Pt6Rh

B

0

1820

°C

400

1820

°C

2

°C typ.

W3Re-W25Re

D

0

2495

°C

500

2495

°C

1

°C typ.

W5Re-W26Re

C

0

2320

°C

500

2320

°C

1

°C typ.

Shortest span

T

y

pe L, J,

U, T

, K, E, N: 50°C

T

y

pe S, R, B: 500°C

T

y

pe D, C: 500

°C

Cold junction

Pt100 inter

n

al

or exter

n

al cold jun

c

tion

(adjustable fr

om 0

to

8

0

°C)

Cold junction

accuracy

± 1

°C

Sampling rate

> 1 measur

ement per secon

d

Sensor curr

ent

350

nA

In

put fil

ter

1st or

de

r di

gi

tal fi

lter;

filter con

stant adjustable fr

om 0

to 100

sec

Special featur

es

can also

be pr

og

rammed in °F;

range limits ar

e f

reely pr

ogrammable;

input isolated fr

om output

1

T

h

e accur

a

cy r

e

fers to

the maximum range span.