6 transmit project to the keypad, Transmit project to the keypad, Hmi designer – Lenze HMI Designer Getting Started Benutzerhandbuch
Seite 44

HMI Designer
L
EDBHMI-DEEN DE/EN 4.0
QKRKS
qк~елгбн йкзаЙЕн нз нЬЙ вЙуй~З
The keypad must be connected to the PC.
( 31)
mêÉé~кЙ вЙуй~З bmjJePNM Сзк нк~елгбллбзе
1. Keep the
F5
key at the keypad pressed.
2. Switch on the supply voltage for the keypad.
3. When “H310 service page” is displayed, release the
F5
key.
pн~кн З~н~ нк~елгбллбзе бе ejf aÉëáÖåÉê
•
Select
Tools
Transfer project... to open the Downloader dialog box.
1. In the section Communication port select the serial interface of your PC which is connected to
the download cable EPZ-H110.
2. In the section Baud rate select the baud rate (default: 115200 baud).
3. Tick Update operating unit program to transmit the program.
Ó If you want to update the system program of the keypad at the same time, mark Update
operating unit firmware in addition.
4. Click
OK to start the data transmission.
•
The program is transmitted to the keypad.
•
After the transmission, the display of the keypad shows the first page (start page) of the project.