tçêâáåÖ пбнЬ нЬЙ йкзЦк~г “péÉÉÇ ЕзенкздТ
The keypad EPM-H310 and the program “Speed control” (H310_93xx.vts) are used to control a
9300 Servo inverter or a 9300 Servo PLC.
mêÉé~к~нбзел зе нЬЙ ЕзенкзддЙк
t~кебеЦ>
Terminal X5/28 on the controller must always be connected to a switch so that you can immediately
set controller inhibit in case of an emergency.
•
Assign control terminals as prescribed (CINH, QSP)
•
Connect system bus (CAN) to the keypad via X4
•
Load basic configuration:
Ó Servo inverter: Basic configuration 1010
Ó 9300 Servo PLC: Load the sample project “SpeedModelInternal24VSupply_CFG1010FUP.pro”
in DDS version V.05 or “Speed Control V10.pro” in DDS version V1.0/V2.0 into the 9300
Servo PLC.
( 38)
•
Configure C0470/1 if necessary to display messages at the keypad
•
Set input X5/E3 = High so that the setpoint can be entered via the keypad
qáé>
Prepare the controller using the following documentation:
( Operating Instructions “9300 Servo inverter”)
or
( Online Manual “9300 Servo PLC” (on the CD-ROM “Drive PLC Developer Studio”)
`зЗЙл Сзк нЬЙ Езенкзд СмеЕнбзел
The controller is controlled or values at the keypad are displayed using the following codes:
Control/display of
Via code
Defined in project component
*
Note
Nmax
C0011
Variables
Acceleration time
C0012
Variables
Deceleration time
C0013
Variables
Nset
C0039/1
Variables
Input in [%] of Nmax
100 % = C0011
Nact
C0051
Variables
Display only
QSP
C0135, bit 3
Variables
Direct commands
Decimal control word
CINH
C0135, bit 9
Message1
C0470/1, bit 0
Device memory areas
Data exchange areas
Information messages
Code must be configured
at the controller
Message2
C0470/1, bit 1
Message3
C0470/1, bit 2
*
42, Project Editor