Seite 48

HMI Designer
L
QU
EDBHMI-DEEN DE/EN 4.0
`зенкзд нЬЙ ЕзенкзддЙк
shift
F1
Esc
F2
F3
F4
F5
Help
Info
F1 => PARAMETER
F2 => CONTROL INVERTER
Controller enable (RFG), quick stop (QSP), Nset,
Nact
•
Press
<shift> + <F2>.
shift
F1
Esc
F2
F3
F4
F5
Help
Info
F1=>RFG:ON
F2=>QSP:OFF
Controller enable (RFG)
1. Press
<Left arrow> or <Right arrow> to go to
line “F1=>RFG:”.
2. Press
<shift> + <F1> to inhibit or enable the
controller.
– “F1=>RFG: ON”: Controller is enabled
– “F1=>RFG: OFF”: Controller is inhibited
Note!
To enable the controller, a HIGH signal must be
applied at terminal X5/28.
Quick stop (QSP)
1. Press
<Left arrow> or <Right arrow> to go to
line “F2=>QSP:”.
2. Press
<shift> + <F2> to set or reset quick
stop.
– “F2=>QSP: ON”: Quick stop is set
– “F2=>QSP: OFF”: Quick stop is reset
shift
F1
Esc
F2
F3
F4
F5
Help
Info
N-SET :100.00%
N-ACT :3000rpm
<F3
Nset, Nact
1. Press
<Down arrow> to go to the next page.
2. Press
<Select parameter> to enter a value for
Nset.
3. Enter the desired value using
<Up arrow> and
<Down arrow>.
4. Confirm with
<Confirm input>.
5. Press
<shift> + <F3> to return to the first page
(start page).
Note!
•
A HIGH signal must be applied at terminal
X5/E3 for the input of the setpoint.
•
“Nact” displays the actual speed of the
controller. You cannot change this value.