2 tabelle parameter spdus, 3 tabelle system kommandos – Baumer BA FADx14 IO Benutzerhandbuch

Seite 15

Advertising
background image

BA_FADK14IO-Link_V01-02-11_DE.doc

15/17

Baumer Electric AG

04.12.2012/rek

Frauenfeld, Switzerland

6.2

Tabelle Parameter SPDUs

S

P

D

U

n

a

m

e

S

P

D

U

i

n

d

e

x

N

u

m

b

e

r

o

f

B

y

te

s

F

o

rm

a

t

R

a

n

g

e

o

f

v

a

lu

e

s

R

/W

C

o

m

m

e

n

ts

Measuring range and switching points

Switching points

work

0X40

4

Switching point A (HB, LB)

Switching point B (HB, LB)

500…4000

R/W Distance information on switching points

Switching points

interim

0X41

4

Switching point A (HB, LB)

Switching point B (HB, LB)

500…4000,

65535

R

Distance information on switching points

Measuring range

work

0X42

4

Measuring range limit A (HB, LB)

Measuring range limit B (HB, LB)

500…4000

R/W Distance information on measuring range

limits

Measuring range

interim

0X43

4

Measuring range limit A (HB, LB)

Measuring range limit B (HB, LB)

500…4000,

65535

R

Distance information on measuring range

limits

Sensor functions

Average

0X50

1

-

0,1,2,4,8,

16

R/W Number of measuring cycles across which

it is being averaged.

Average value = 0 or 1: Average is

switched off.

Output function

switching output

0X62

1

0 = ON, if there is no valid signal

within MB

1 = Switching output defined by

switching points

2 = ON if signal falls below

excess gain signal threshold

0,1,2

R/W Indicates what function is available on the

output.

Nominal value

quality parameter

0X65

1

1..8

R/W Provided the internal quality parameter

drops below this threshold the switching

output is set.

Quality parameter

0X66

1

1..8 or 255

R

6.3

Tabelle System Kommandos

N

a

m

e

o

f

C

o

m

-

m

a

n

d

S

P

D

U

I

n

d

e

x

C

M

D

V

a

lu

e

C

o

m

m

e

n

ts

Restore factory setting 0X02

0X82

Restores all original factory settings of the sensor

Teach-in

switching point A

0X02

0XA0

Teach-in of switching point A. The measured distance is written into the interim switching

points register.

Teach-in

switching point B

0X02

0XA1

Teach-in of switching point B. The measured distance is written into the interim switching

points register.

Transfer

switching points

0X02

0XA2

Transfer of the switching points from the interim register to the working register.

Teach-in measuring

range limit A

0X02

0XA3

Teach-in of measuring range limit A. The measured distance is written into the measuring

range interim register

Teach-in measuring

range limit B

0X02

0XA4

Teach-in of measuring range limit B. The measured distance is written into the measuring

range interim register.