6.2
Tabelle Parameter SPDUs
S
P
D
U
n
a
m
e
S
P
D
U
i
n
d
e
x
N
u
m
b
e
r
o
f
B
y
te
s
F
o
rm
a
t
R
a
n
g
e
o
f
v
a
lu
e
s
R
/W
C
o
m
m
e
n
ts
Measuring range and switching points
Switching points
work
0X40
4
Switching point A (HB, LB)
Switching point B (HB, LB)
500…4000
R/W Distance information on switching points
Switching points
interim
0X41
4
Switching point A (HB, LB)
Switching point B (HB, LB)
500…4000,
65535
R
Distance information on switching points
Measuring range
work
0X42
4
Measuring range limit A (HB, LB)
Measuring range limit B (HB, LB)
500…4000
R/W Distance information on measuring range
limits
Measuring range
interim
0X43
4
Measuring range limit A (HB, LB)
Measuring range limit B (HB, LB)
500…4000,
65535
R
Distance information on measuring range
limits
Sensor functions
Average
0X50
1
-
0,1,2,4,8,
16
R/W Number of measuring cycles across which
it is being averaged.
Average value = 0 or 1: Average is
switched off.
Output function
switching output
0X62
1
0 = ON, if there is no valid signal
within MB
1 = Switching output defined by
switching points
2 = ON if signal falls below
excess gain signal threshold
0,1,2
R/W Indicates what function is available on the
output.
Nominal value
quality parameter
0X65
1
1..8
R/W Provided the internal quality parameter
drops below this threshold the switching
output is set.
Quality parameter
0X66
1
1..8 or 255
R
6.3
Tabelle System Kommandos
N
a
m
e
o
f
C
o
m
-
m
a
n
d
S
P
D
U
I
n
d
e
x
C
M
D
V
a
lu
e
C
o
m
m
e
n
ts
Restore factory setting 0X02
0X82
Restores all original factory settings of the sensor
Teach-in
switching point A
0X02
0XA0
Teach-in of switching point A. The measured distance is written into the interim switching
points register.
Teach-in
switching point B
0X02
0XA1
Teach-in of switching point B. The measured distance is written into the interim switching
points register.
Transfer
switching points
0X02
0XA2
Transfer of the switching points from the interim register to the working register.
Teach-in measuring
range limit A
0X02
0XA3
Teach-in of measuring range limit A. The measured distance is written into the measuring
range interim register
Teach-in measuring
range limit B
0X02
0XA4
Teach-in of measuring range limit B. The measured distance is written into the measuring
range interim register.