4 tabelle fehlercodes, 5 tabelle werkseinstellungen – Baumer BA FADx14 IO Benutzerhandbuch
Seite 16
BA_FADK14IO-Link_V01-02-11_DE.doc
16/17
Baumer Electric AG
04.12.2012/rek
Frauenfeld, Switzerland
Transfer
measuring range
0X02
0XA5
Transfer of the measuring range from the interim register to the working register
Save parameters
0X02
0XE0
Save all parameters in Flash memory
6.4
Tabelle Fehlercodes
E
rr
o
r
C
a
s
e
E
rr
o
r
C
o
d
e
1
E
rr
o
r
C
o
d
e
2
D
e
s
c
ri
p
ti
o
n
o
f
E
rr
o
r
C
o
d
e
s
Communication error
(Checksum, …)
0x10
0x00
Communication error, No details
Length of written SPDU is wrong
0x10
0x00
Communication error, No details
Reading an unimplemented SPDU
0x80
0x11
Device error, Index not available
Writing to an unimplemented SPDU
0x80
0x11
Device error, Index not available
Reading Index 2
0x80
0x23
Device error, Access denied
Writing to a read only SPDU
0x80
0x23
Device error, Access denied
Writing an unimplemented System Command 0x80
0x23
Device error, Access denied
Distance between two tought points too small 0x80
0x40
Device error, Interfering parameter
Written parameter out of defined range
0x80
0x30
Device error, Parameter value out of range
6.5
Tabelle Werkseinstellungen
S
P
D
U
n
a
m
e
S
P
D
U
i
n
d
e
x
D
e
fa
u
lt
v
a
lu
e
Application Specific Name
0X18
empty
Switching points work
0X40
Switching point A: 50mm
Switching point B: 400mm
Measuring range work
0X42
Measuring range limit A: 50mm
Measuring range limit B: 400mm
Average
0X50
0 (keine Mittelung)
Output function switching output
0X62
0 (Alarm)
Nominal value
quality parameter
0X65
7