4 tabelle fehlercodes, 5 tabelle werkseinstellungen – Baumer BA FADx14 IO Benutzerhandbuch

Seite 16

Advertising
background image

BA_FADK14IO-Link_V01-02-11_DE.doc

16/17

Baumer Electric AG

04.12.2012/rek

Frauenfeld, Switzerland

Transfer

measuring range

0X02

0XA5

Transfer of the measuring range from the interim register to the working register

Save parameters

0X02

0XE0

Save all parameters in Flash memory

6.4

Tabelle Fehlercodes

E

rr

o

r

C

a

s

e

E

rr

o

r

C

o

d

e

1

E

rr

o

r

C

o

d

e

2

D

e

s

c

ri

p

ti

o

n

o

f

E

rr

o

r

C

o

d

e

s

Communication error

(Checksum, …)

0x10

0x00

Communication error, No details

Length of written SPDU is wrong

0x10

0x00

Communication error, No details

Reading an unimplemented SPDU

0x80

0x11

Device error, Index not available

Writing to an unimplemented SPDU

0x80

0x11

Device error, Index not available

Reading Index 2

0x80

0x23

Device error, Access denied

Writing to a read only SPDU

0x80

0x23

Device error, Access denied

Writing an unimplemented System Command 0x80

0x23

Device error, Access denied

Distance between two tought points too small 0x80

0x40

Device error, Interfering parameter

Written parameter out of defined range

0x80

0x30

Device error, Parameter value out of range

6.5

Tabelle Werkseinstellungen

S

P

D

U

n

a

m

e

S

P

D

U

i

n

d

e

x

D

e

fa

u

lt

v

a

lu

e

Application Specific Name

0X18

empty

Switching points work

0X40

Switching point A: 50mm

Switching point B: 400mm

Measuring range work

0X42

Measuring range limit A: 50mm

Measuring range limit B: 400mm

Average

0X50

0 (keine Mittelung)

Output function switching output

0X62

0 (Alarm)

Nominal value

quality parameter

0X65

7

Advertising