BE134

16 www.baumer.com

0 *

Ph main counter - reset static

1

Ph main counter - reset pulse edge active

2

Ph main counter and totalizer - stop

3

Hold

4

Programming lock

5

Key lock

6

Print (min. pulse duration 30ms)

Line 35

Minimum pulse duration for control input 1

0 *

30 ms

1

100 µs

Line 36

Function control input 2 (port 10)

0

Ph main counter - reset static

1

Ph main counter - reset pulse edge active

2 *

Ph main counter and totalizer – stop

3

Hold

4

Programming lock

5

Key lock

6

Print

7

ext. counting input for batch counter

Line 37

Function control input 3 (port 11)

0 *

tot Totalizer - reset static

1

tot Totalizer - reset pulse edge active

2

b Batch counter - reset static

3

b Batch counter - reset pulse edge active

4

Programming lock

5

Key lock

6

Print

7

ext. counting input for batch counter

Line 38

Taking over of the preselections P1, P2

0 *

Effective immediately after input

1

Not effective until the counter has been
reset

Line 40

Output logic

0 *

Both outputs as make contacts

1

P1 break contact, P2 make contact

2

P1 make contact, P2 break contact

3

Both outputs as break contacts

Line 41

Pulse signal duration P1

0.01

Minimum signal duration

0.25 * Default
99.99

Maximum signal duration

Latch

Permanent signal (by pressing the key C)

Line 42

Pulse signal duration P2

0.01

Minimum signal duration

0.25 * Default
99.99

Maximum signal duration

Latch

Permanent signal (by pressing the key C)

Line 50

Code setting

0000 * Code not active
:

9999

Line 51

Baud rate

0 *

4800 baud

1

2400 baud

2

1200 baud

3

600 baud

Line 52

Parity

0 *

Even parity

1

Odd parity

2

No parity

Line 53

Stop bits

0 *

1 Stop bit

1

2 Stop bits

Line 54

Address

00 *

Default

00

Min.

99

Max.