Setup menu

General

The Setup menu allows you to retrieve present device settings and change parameters.

WARNING! Operating the equipment incorrectly can cause serious damage.
The functions described must only be carried out by trained and qualified
personnel. In addition to the safety rules in these operating instructions, the
safety rules of the battery and vehicle manufacturer must also be followed.

Safety

Max. output voltage (factory setting: 28 V DC)
Setting range: 1 - 28.8 V DC

Access the Setup
menu

1.

To enter the Setup menu, press the buttons

Save setting and go to next menu item

Move to next setting, e.g. for time setting (hh:mm:ss) move from hours (hh) to
minutes (mm)

Increase value

Reduce value

+

together for approx. 20 seconds

Navigation in the
Setup menu

Selected service level is displayed (no „Service Level 1“ in this device available)

Setting range of
the parameters

Max. operating hours limit (factory setting: off)
Setting range: 1 min. - 24 h

Max. output current (factory setting: 100 A)
Setting 0.5 - 100 A