Pressure loss coefficient for promass s, p, Pressure loss (us units) – FMC Corporation - Talstar 80 Benutzerhandbuch

Seite 108

Advertising
background image

Technical data

Proline Promass 80 PROFIBUS PA

108

Pressure loss coefficient for Promass S, P

a0004607

Fig. 48:

Pressure loss diagram for water

Pressure loss (US units)

Pressure loss is dependent on fluid properties nominal diameter. Consult FMC Technologies for
Applicator PC software to determine pressure loss in US units. All important instrument data is
contained in the Applicator software program in order to optimize the design of measuring system.
The software is used for following calculations:

• Nominal diameter of the sensor with fluid characteristics such as viscosity, density, etc.
• Pressure loss downstream of the measuring point.
• Converting mass flow to volume flow, etc.
• Simultaneous display of various meter size.
• Determining measuring ranges.

The Applicator runs on any IBM compatible PC with windows.

DN

d[m]

K

K1

K3

8

8.31

⋅ 10

–3

8.78

⋅ 10

6

3.53

⋅10

7

1.30

⋅ 10

6

15

12.00

⋅ 10

–3

1.81

⋅ 10

6

9.99

⋅ 10

6

1.87

⋅ 10

5

25

17.60

⋅ 10

–3

3.67

⋅ 10

5

2.76

⋅ 10

6

4.99

⋅ 10

4

40

26.00

⋅ 10

–3

8.00

⋅ 10

4

7.96

⋅ 10

5

1.09

⋅ 10

4

50

40.50

⋅ 10

–3

1.41

⋅ 10

4

1.85

⋅ 10

5

1.20

⋅ 10

3

Pressure loss data includes interface between measuring tube and piping

1000

100

10

1

0.1

0.01

0.1

1

10

100

[mbar]

[t/h]

DN 40

DN 50

DN 25

DN 15

DN 8

Advertising