Proline Promass 80 PROFIBUS PA

14

3.1.3

Storage

Note the following points:
• Pack the measuring device in such a way as to protect it reliably against impact for storage (and

transportation). The original packaging provides optimum protection.

• The permissible storage temperature is –40 to +80 °C (–40 °F to +176 °F), preferably +20 °C

(+68 °F).

• Do not remove the protective covers or caps on the process connections until you are ready to

install the device.

• The measuring device must be protected against direct sunlight during storage in order to avoid

unacceptably high surface temperatures.

3.2

Installation conditions

Note the following points:
• No special measures such as supports are necessary. External forces are absorbed by the

construction of the instrument, for example the secondary containment.

• The high oscillation frequency of the measuring tubes ensures that the correct operation of the

measuring system is not influenced by pipe vibrations.

• No special precautions need to be taken for fittings which create turbulence (valves, elbows,

T-pieces, etc.), as long as no cavitation occurs.

• For mechanical reasons and in order to protect the pipe, it is advisable to support heavy sensors.

3.2.1

Dimensions

All the dimensions and lengths of the sensor and transmitter are provided in the separate
documentation "Technical Information"

3.2.2

Mounting location

Entrained air or gas bubbles forming in the measuring tube can result in an increase in measuring
errors.
Avoid the following locations in the pipe installation:
• Highest point of a pipeline. Risk of air accumulating.
• Directly upstream of a free pipe outlet in a vertical pipeline.

a0003605

Fig. 6:

Mounting location

The proposed configuration in the following diagram, however, permits installation in a vertical
pipeline. Pipe restrictors or the use of an orifice plate with a smaller cross-section than the nominal
diameter prevent the sensor from running empty during measurement.