Panel settings menu – FUJITSU Primergy Blade Server Systems BX600 Benutzerhandbuch

Seite 77

Advertising
background image

Panel Settings Menu

Web-Based Management Interface

Intelligent Blade Panel Module

76

6.2.2.1.10 Configuring SNTP

Configuring SNTP Global Configuration Page

Configurable Data

Client Mode

- Specifies the mode of operation of SNTP Client. An SNTP client may

operate in one of the following modes.

Disable

- SNTP is not operational. No SNTP requests are sent from the client

nor are any received SNTP messages processed.

Unicast

- SNTP operates in a point to point fashion. A unicast client sends a

request to a designated server at its unicast address and expects a reply from which it
can determine the time and, optionally the round-trip delay and local clock offset
relative to the server.

Broadcast

- SNTP operates in the same manner as multicast mode but uses a

local broadcast address instead of a multicast address. The broadcast address has a
single subnet scope while a multicast address has Internet wide scope. Default value
is Disable.

Port

- Specifies the local UDP port to listen for responses/broadcasts. Allowed range is (1

to 65535). Default value is 123.

Unicast Poll Interval

- Specifies the number of seconds between unicast poll requests

expressed as a power of two when configured in unicast mode. Allowed range is (6 to 10).
Default value is 6.

Broadcast Poll Interval

- Specifies the number of seconds between broadcast poll

requests expressed as a power of two when configured in broadcast mode. Broadcasts
received prior to the expiry of this interval are discarded. Allowed range is (6 to 10).
Default value is 6.

Unicast Poll Timeout

- Specifies the number of seconds to wait for an SNTP response

when configured in unicast mode. Allowed range is (1 to 30). Default value is 5.

Unicast Poll Retry

- Specifies the number of times to retry a request to an SNTP server

after the first time-out before attempting to use the next configured server when
configured in unicast mode. Allowed range is (0 to 10). Default value is 1.

Command Buttons

Submit

- Sends the updated configuration to the IBP. Configuration changes take effect

immediately.

Advertising