Installation

Installing the appliance horizontally in the 1U rack mounting space

7

590-595-609A

Reliable earthing: Maintain reliable earthing of rack-mounted equipment. Pay
particular attention to supply connections other than direct connections to the
branch circuit (for example, use of power strips).

2.3.2

Installing the appliance horizontally in the 1U rack
mounting space

The filler panel must be placed in front of the rack when the appliance is mounted in the
horizontal 1U orientation.


Remove the screws on each side of the appliance.



Line up the holes in the long side of each mounting bracket.



With a Phillips screwdriver, fasten the mounting brackets to the appliance using
three 8/32 in. x 1/2 in. pan-head screws on each side.



Attach four cage nuts or clip nuts to the rack mounting flange of the rack so that the
nut is positioned on the inside of the rack.



As shown in Figure 3, mount the appliance assembly to the rack by matching the
holes in the short side of each mounting bracket to a set of matching holes on the
rack. Insert the combination hex-head screws through the slots in the mounting
bracket and the holes in the mounting rail, then into the cage nuts or clip nuts.

Figure 3: Appliance horizontal installation