WIKA operating instructions RTD and TC, intrinsically safe designs (Ex i)

3345267.12 01/2014 GB/D

27

GB

7.3.2 Increasing the separation of the connection components and hot surfaces

The neck distance (N) is defined as the distance between the lower edge of the connection head

(or the housing) to the heat-emitting surface. The temperature to be expected at the lower edge

of the connection head or housing is, at most, 100 °C. The conditions for built-in transmitters or

displays must be observed. If required, the neck length must be increased accordingly.

For thermometers fitted with a connection lead, the temperature at the interface with the

connecting cable is restricted. The maximum is 150 °C. To ensure that the permissible

temperature is not exceeded, the dimension X must be selected accordingly.

7. Information on mounting, operation in hazardous area (Europe)

3160670.06

Threaded connection

Thread

Thread

11355647.01

Thread

Thread

(NPT)