Probes for water and oil 43, 9 probes for air, 10 probes for water and oil – JUMO 14597 safetyM TB/TW08 Temperature Limiter and Temperature Monitor Operating Manual Benutzerhandbuch

Seite 105

Advertising
background image

9 Probes for air

43

2014-06-12

10

Probes for water and oil

901006/66-953-1046-6-250-668/000

90.027

1 x PT30Rh-PT6Rh, Typ

E „B“

600 ... 1500°C

250

901006/66-953-1046-6-355-668/000

90.028

355

901006/66-953-1046-6-500-668/000

90.029

500

901006/66-953-2046-6-250-668/000

90-D-027

2 x PT30Rh-PT6Rh, Typ

E „B“

600 ... 1500°C

250

901006/66-953-2046-6-355-668/000

90-D-028

355

901006/66-953-2046-6-500-668/000

90-D-029

500

Note: Because of the high response accuracy, the use of thermowells (pockets) is not admissible.

Actual type designation

Old type
designation

Probe type

Temperature range

Nom. length mm

P

rocess connection

RTD temperature probe Data Sheet 90.2006

90.2006/10-402-1003-1-9-100-104/000

1 x Pt100

-40 ... +400°C

100

G1/2 screw connection

90.2006/10-402-2003-1-9-100-104/000

2 x Pt100

100

902006/54-227-2003-1-15-710-254/000

90.272-F02

2 x Pt100

-170 ... 550°C

65...670

movable
G1/2 compression clamp

902006/54-227-1003-1-15-710-254/000

90.272-F03

1 x Pt100

65...670

902006/10-226-1003-1-9-250-104/000

90.239

1 x Pt100

-170 ... 480°C

250

G1/2 screw connection

902006/10-226-2003-1-9-250-104/000

90-D-239

2 x Pt100

250

Thermocouples Data Sheet 90.1006

901006/54-544-2043-15-710-254/000

90.020-F02

2 x NiCr-Ni, Type „K“

-35 ... 550°C

65...670

movable
G1/2 compression clamp

901006/54-544-1043-15-710-254/000

90.020-F03

1 x NiCr-Ni, Type „K“

65...670

901006/54-544-2042-15-710-254/000

90.020-F12

2 x FeCuNi, Type „L“

65...670

901006/54-544-1042-15-710-254/000

90.020-F13

1 x FeCuNi, Type „L“

65...670

Advertising