Product description

Connections and interfaces

2

EN

29

Lenze ¯ MDKSEMA ¯ 3.0

2.2

Connections and interfaces

)

Note!

You only have to open the cover of the Lenze Smart motor if you connect
an external brake resistor or if you implement the mains connection
without a QUICKON connector.

1.7 Nm

(15 lb-in)

PE

X1

X2

X5

X3

X4

1.7 Nm

(15 lb-in)

MSEMA_001

X1, X2

Control connections, M12 connectors, A−coded, pins

X3

Mains connection, QUICKON connector or M25 x 1.5 cable gland

X4

Connection of external brake resistor, M12 x 1.5 cable gland

X5

Connection of spring−applied brake (pre−wired at delivery)

PE

Connection of second PE conductor