2 fault messages, Fault messages, Troubleshooting and fault elimination – Lenze M300 Benutzerhandbuch

Seite 45: En 45

Advertising
background image

Troubleshooting and fault elimination

Fault messages

6

EN

45

Lenze ¯ MDKSEMA ¯ 3.0

6.2

Fault messages

Fault

Possible cause

Remedy

Type Message

F

RFID read error (RFIR)

NFC communication interrupted

1. Connect and disconnect mains.
2. Repeat action.
3. If the error occurs again, please contact

the Lenze Service.

F

RFID write error (RFIW)

F

RFID data CRC invalid (PS02)

NFC communication interrupted

1. Load default setting.
2. Connect and disconnect mains.
3. Rewrite parameter set.

F

RFID data version invalid (PS04)

Incompatible software version

Update Lenze App or EASY Starter.

F

Missing mains phase (SU02)

A mains phase of a three−phase supply has
failed.

¯

Check mains connection.

¯

Check fuses.

F

DC bus overvoltage (OU)

DC−bus voltage too high

¯

Increase deceleration ramp.

¯

Reduce speed for great regenerative
loads.

¯

Use brake resistor.

W

Electronics warning temperature (OH4)

Lacking or insufficient cooling.
Drive close to being disconnected due to
overtemperature (OH1)

¯

Check cooling.

¯

Clean cooling ribs.

F

Electronics overtemperature (OH1)

Ambient temperature too high.

Ambient temperature must be in the
permissible range.

F

Electronics overload (Ixt ) (OC9)

The Ixt overload test has been triggered
¯

Motor load too high.

¯

Load cycles not complied with.

¯

Increase deceleration ramp.

¯

Reduce I

max

.

¯

Check dimensioning.

F

Electronics overcurrent (OC11)

Overcurrent limitation active

¯

Reduce motor load.

¯

Increase deceleration ramp.

F

Motor overcurrent (OC7)

The maximum current monitoring
function has been triggered.

Reduce motor load.

F

Motor short circuit (OC1)

Short circuit in the motor phases

Reset error. If the error occurs again during
restart, please contact the Lenze Service.

F

Motor earth fault (OC2)

A motor phase has earth contact

F

Motor overload (I

2

xt) (OC6)

Motor thermally overloaded

¯

Reduce motor load.

¯

Check setting of the I

2

xt monitoring

function.

¯

Increase deceleration ramp.

F

Brake resistor overload (I

2

xt )

Too frequent and too long braking
processes

Check drive dimensioning.

Lenze Smart motor without brake resistor:
DC−bus voltage too high

¯

Reduce regenerative load.

¯

Use brake resistor.

¯

Increase deceleration ramp.

F

Internal error (DH69)

Various

Reset error. If the error occurs again during
restart, please contact the Lenze Service.

F

Internal error (DF01)
...
Internal error (DF13)

Various

Advertising