Troubleshooting and fault elimination

Drive behaviour in the event of faults

6

EN

44

Lenze ¯ MDKSEMA ¯ 3.0

6

Troubleshooting and fault elimination

6.1

Drive behaviour in the event of faults

Fault messages are stored in the Lenze Smart motor.

How to read out the fault messages:

1. Disconnect Lenze Smart motor from the mains.

2. Load parameter set to the Smartphone or the EASY Starter.

Under "History", the last 4 messages are stored.

How to reset errors:

3. Eliminate the cause of malfunction.

4. The error has been reset.

You can restart the drive.

I

Tip!

You can reset the fault without mains switching:
Select the input speed 0 rpm via the digital inputs.
Then select the desired speed again.
If the cause of malfunction is no longer active, the drive will restart.

Fault

Drive behaviour

Type

Meaning

F

Error

The digital output changes to LOW = not ready for operation.
The fault is entered in the history buffer.
¯

Lenze Smart motor without brake: The motor is switched off and coasts down.

¯

Lenze Smart motor with brake: The motor is switched off; the brake is applied.

W

Warning

The fault is entered in the history buffer.
The Lenze Smart motor continues running.