Lenze ¯ MDKSEMA ¯ 3.0

Advanced settings

Parameter

Value

Comment

Name

Delivery

Setting range

Vmin boost

0.0 %

[0.0 ... 100.0] %

Boost of the motor voltage in the range of low
speeds.
In the case of conveyor applications with an
inclined proportion, a turn−back during
start−up can be prevented.
Typical values approx. < 5%.

Imax in motor mode

Device−depende
nt

[0.00 ... Imax] A

Maximum motor current
MSEMAxx063−42: 5.6 A
MSEMAxx080−32: 13.2 A
With a gearbox, the setting range can be
smaller.
Reduction of I

max

limits the load−dependent

starting torque.

Motor overload setting (I

2

xt)

100.00 %

[0.00 ... 250.00] %

Setting for operation at an ambient
temperature of up to + 40 °C optimised.

Starting value for motor
overload (I

2

xt)

50.00 %

[0.00 ... 100.00] %

Recommended setting for operation
according to UL: 50.00 %

Motor brake switching
threshold

100 rpm

[0 ... 499.9/i] rpm

Motor brake is switched if the value is
exceeded or is too low.
Higher value:
In the case of conveyor applications with an
inclined proportion, a turn−back during
start−up can be prevented.

Brake resistor R

150.0 Ohm

[150.0 ... 500.0] Ohm

Enter data of a connected brake resistor.
The optional internal brake resistor is set by
default.

Rated power of brake resistor

10 W

[10 ... 65535] W

Thermal capacity of brake
resistor

0.6 kWs

[0 ... 6553.5] kWs

Reduction of brake chopper
threshold

0 V

[0 ... 150] V

The threshold is reduced by the voltage value
set here.
The switching threshold is adapted to the
different mains voltage ranges.
Reduction by 20 ... 30 V can prevent
overvoltage for operation in generator mode.

Impact of oscillation damping

5.00 %

[0.00 ... 250.00] %

To suppress idle oscillations. Typically, the
impact has to be increased for this purpose.

Oscillation damping filter time 50 ms

[2 ... 250] ms

Logbook

Parameter

Value

Comment

Name

Delivery

Setting range

Error message 1 (last)

[text]

Meaning: see fault message table

Error message 2

[text]

Error message 3

[text]

Error message 4 (earliest)

[text]

Meters

Parameter

Value

Comment

Name

Delivery

Setting range

Elapsed−hour meter

[0 ... 596523] h

Total time of "Motor rotating"

Operating−hour meter

[0 ... 596523] h

Total time of "mains ON"