Lenze 931ExK10 Benutzerhandbuch

Seite 34

Advertising
background image

34

MA 13.0001 DE-EN DE/EN 2.0

LED

Colour

State

Note

State

Green

on

The control is correctly supplied by a 24 V control voltage, the drive is

ready for operation.

blinking

Data is written on or read from the memory card.

off

No voltage

Power

Yellow

on

The power section is enabled, the motor is supplied with voltage. The

drive works with the set control.

off

The drive does not work, the output stage is inactive.

Error

Red

off

No fault

blinking

Internal drive error

1)

After the cause of the error has been eliminated, you have to

acknowledge the error message:

z

Either by using the parameterisation software, or via an edge at

DIN9 (controller enable).

z

If no error is active anymore, the LED goes out.

Green

Yellow

Red

on

z

The drive is in the initialisation phase after the control voltage has

been switched on.

z

A new firmware is being installed.

1)

Detailed description of the blink code: see Hardware Manual.

Note!

The light-emitting diode ”Error” constantly blinks if a fault is active:

ƒ

It only displays one fault at a time.

ƒ

If several faults are active at the same time, the fault that occured first is

displayed.

Advertising