4 motor connection, Motor connection, Electrical installation – Lenze 931ExK10 Benutzerhandbuch

Seite 51: Stop

Advertising
background image

Electrical installation

Motor connection

4

51

MA 13.0001 DE-EN DE/EN 2.0

4.4

Motor connection

X3 motor connection
Pin No.

Designation

Specification

1

U

Motor phases

Fundamental wave in

case of overload for 2 s

up to 32 A

eff

approx. 0 V ... 27 V

eff

2

V

0 V ... 13 A

eff

3

W

0 Hz ... 200 Hz

4

BR+

Brake

24V DC

5

BR-

0 V

Terminal data

Max. conductor

cross-section

Tightening torque

Screw drive

Cable

[mm

2

]

[AWG]

[Nm]

[lb-in]

Flexible

7 mm

2.5

12

0.5 ... 0.6

4.4 ... 5.3

Slot 0.6 x 3.5

With wire end

ferrule

Stop!

The brake is supplied by the control voltage at X2. In order to ensure

the trouble-free operation of the brake, the control voltage has to

be in the tolerance range of the brake used!

Advertising