2 technical data, 1 general data and operating conditions, Technical data – Lenze 931ExK10 Benutzerhandbuch

Seite 42: General data and operating conditions, 2technical data

Advertising
background image

Technical data

General data and operating conditions

2

42

MA 13.0001 DE-EN DE/EN 2.0

2

Technical data

2.1

General data and operating conditions

Conformity

CE

Low-Voltage Directive 73/23/EEC

Regulations

EN 61800-3

Interference level B

Climatic conditions

Air humidity max. 90 % without condensation

Cooling

Passively via housing surface and rear panel

Permissible temperature ranges

Transport

-25 °C... +70 °C

Storage

-25 °C... +70 °C

Operation

0 °C ... +50 °C

above +40 °C, reduce the power by

20 W/°C

Permissible installation height

0 ... 1000 m amsl

above 1000 m amsl, reduce the rated

output current by 5 %/1000 m

Mounting position

Vertical

Mounting clearances

above/below

100 mm

sidewise

Directly alignable

Monitoring

Overvoltage / undervoltage in the DC bus, overcurrent or

short circuit of the output stage, motor temperature and

output stage temperature, I

2x

t-monitoring of the motor,

encoder monitoring

Type of protection

IP 20

Inputs

6 digital inputs, 2 analog inputs

(adjustable via software)

Outputs

2 digital outputs, 2 analog outputs

(adjustable via software)

Bus system

CAN (DS301, DSP402)

Memory cards

Multimedia card

Advertising