2 technical data, 1 general data and operating conditions, Technical data – Lenze ELCAMZIxxx4SNNPSNN (LCU 122) Benutzerhandbuch

Seite 48: General data and operating conditions, 2technical data

Advertising
background image

Technical data

General data and operating conditions

2

l

48

EDKLCMZ3024−SPS DE/EN 4.0

2

Technical data

2.1

General data and operating conditions

General data

Values

Conformity

CE

Low−Voltage Directive (73/23/EC)
EMC Directive (93/68/EEC)

Standards

DIN EN 60947−4−2 Semiconductor motor control units and motor starters for

AC voltage

EN954 KAT3

Safe torque off (STO) according to category 3

General technical data

Values

EMC

Compliance with the requirements in accordance with EN 60947−4−2

Noise emission

Compliance with limit class B in accordance with EN 60947−4−2

Leakage current to PE
(according to EN 50178)

< 3.5 mA

Enclosure

IP 54

All connectors that are not used have to be closed by
means of protection covers or blanking plugs.

NEMA 250 type 4

Protective measures against

Motor overtemperature
(input for PTC or thermal contact, I

2

t monitoring)

Protective insulation of control
circuits

Safe disconnection from mains:
double/reinforced insulation to EN 50178

Insulation resistance

Overvoltage category III to VDE 0110

Service switch

Rotary switch, triple locking
reset feedback contact for status message and fault message (TRIP reset)

Operating conditions

Values

Deviating values

Mechanical tests

Accelerational stability

Up to 1 g in accordance with
Germanischer Lloyd, general
conditions

Vibration resistance

In accordance with EN 50178 or
EN 60068−2−6

Impingement resistance

2m2 in accordance with
IEC/EN 60721−3−2

Ambient conditions

Climatic conditions

Storage 1k3 in accordance with

IEC/EN 60721−3−1

−25 °C ... +70 °C

Transport 2k3 in accordance with

IEC/EN 60721−3−2

Operation 3k3 in accordance with

IEC/EN 60721−3−3

−10 °C ... +45 °C

Site altitude

0 ... 4000 m amsl

Reduce the rated output current by 5%/1000
m above 1000 m amsl.

Degree of pollution

2 in accordance with VDE 0110 part 2

Mounting location

Mounting positions

vertical Motor plug downwards

horizontal Front cover upwards

Mounting clearances

above

^ 53

The actual free space is determined by the

t

d

d th

bl b

di

dii

Advertising