Electrical installation – Lenze ELCAMZIxxx4SNNPSNN (LCU 122) Benutzerhandbuch

Seite 64

Advertising
background image

Electrical installation

Control connections

4

l

64

EDKLCMZ3024−SPS DE/EN 4.0

Digital outputs

)

Note!

If inductive loads are being connected, it is essential to use a spark suppressor
at the digital output.

X45 − digital outputs A1, A2

Pin

Signal

Description

Data

Connector: socket, 4−pole, M12

1

+24 V

Supply

2

Signal 1

a1

HIGH

U

DC

at X11

3

GND

Reference potential

LOW

0 ... +4 V

4

Signal 2

A2

Max. 500 mA

Diagnostic interface

X70 − Diagnostic interface

Pin

Signal

Description

Data

1 ... 4

Connection for handheld keypad or PC
interface

Connector: Plug connector, 4−pin
Connection only possible using a Lenze
system cable E82ZWLxxx
Only use PC interfaces featuring electrical
isolation:
LECOM−A (RS232) EMF2102IBCV004 or
LECOM A/B (RS232/RS485)
EMF2102IBCV001

Automatic / manual operation

)

Note!

Manual operation is only possible if the motor starter is enabled by the safety
PLC!

X72

1)

− Manual operation

Pin

Signal

Description

Data

Connector: Socket, 8−pin, M12

1

+24 V

Supply (switch in manual operation)

2

Signal 1

Input automatic/manual operation

HIGH

Manual operation

LOW

Automatic operation

3

GND

Reference potential

4

HI1

Input 1

HIGH

CW rotation

5

HI2

Input 2

HIGH

CCW rotation

6 ... 8

Reserved

1)

Designation in production lot with hardware version PB: X20

Advertising