3 mains connection, Mains connection, Electrical installation – Lenze ELCAMZIxxx4SNNPSNN (LCU 122) Benutzerhandbuch

Seite 57

Advertising
background image

Electrical installation

Mains connection

4

l

57

EDKLCMZ3024−SPS DE/EN 4.0

4.3

Mains connection

lcu12x_000c

X10 − Mains connection

Pin

Connection

Description

Data

Connector: Pins, Harting HAN−Modular

a1

L1

Phase L1

3/PE AC 320 V − 0% ... 530 V + 0%

a2

L2

Phase L3

a3

L3

Phase L3

+

PE

PE conductor

X11 − 24 V DC connection

Pin

Connection

Description

Data

Connector: Pins, Harting HAN−Modular

b1

24 V DC

Voltage supply for control electronics

Safely isolated power supply unit
(SELV/PELV)
+24 V DC
(+20 V DC − 0% ... +26.5 V DC + 0%)
Max. 5 A

b2

n. c.

Not assigned

b3

GND

Reference potential