Technical data

Rated data

931MxKx1 servo drive

2

l

53

MA 13.1002 DE−EN DE/EN 1.1

Type

931MxKx1 −

SDSGSxx035

931MxKx1 −

SDSGSxx047

24 V

DC

42 V

DC

42 V

DC

Brake

Voltage

U

DC

[V]

24 (± 10 %)

Current

I [A]

Approx. 1

Open and closed loop control

Control method

Torque, speed, following error and position control

Cycle time

Current controller

t [

ms]

£ 100

Speed controller

Minimally 500

Following error

Position controller

Chopper frequency (PWM)

f [kHz]

10

Max. output frequency

f [Hz]

500

Positioning range

Revolutions

± 2

19

Storable function data records

100

Encoder evaluation

Resolver (12 bit internal resolution)

Monitoring

Over/undervoltage, temperature of the motor and the
output stage

1) Forces for a bearing life of 20000 h
2) The idling speed indicates the max. possible speed of the drive system under

no−load condition depending on the supply voltage of the inverter.

3) Maximum torque at a speed of 0 min

−1

to 500 min

−1

4) Maximum torque at rated speed

Advertising