Electrical installation

Electrical connections 931MxKx1

4

l

67

MA 13.1002 DE−EN DE/EN 1.1

X5 local CAN (option)

Contact pattern

Pin No. Signal

Specification

1

DC + 5 V

Voltage supply

2

CAN_H

CAN HIGH

3

CAN_GND CAN Ground

4

CAN_L

CAN LOW

X4.1 / X4.2 PROFIBUS (option)

Input contact pattern

Pin No. Signal

Specification

1

n. c.

Not assigned

2

RxD/TxD−N

Receive / Transmit data −N (A line)

3

DGND

Data Ground (reference potential to VP)

4

RxD/TxD−P

Receive / Transmit data −plus (B line)

5

Shield

Shield

Output contact pattern

Pin No. Signal

Specification

1

VP

Power supply plus (5V)

2

RxD/TxD−N

Receive / Transmit data −N (A line)

3

DGND

Data Ground (reference potential to VP)

4

RxD/TxD−P

Receive / Transmit data −plus (B line)

5

Shield

Shield

1

CAN_SHLD

CAN_Shield

2

Ċ

Reserved

3

CAN_GND

CAN_Ground

4

CAN_H

CAN_HIGH (high is
dominant)

5

CAN_L

CAN_LOW (low is dominant)