Status display: device, Status display: fieldbus interface, Status display: drive−based safety – Lenze ELCAFHIxxx4D34NNPM Highline Benutzerhandbuch

Seite 45

Advertising
background image

l

45

EDKLCFH3024−XPM DE/EN 6.0

Status display: device

Pos.

Colour

State

Description

ERR

Red

Off

No fault

Blinking

Active fault

RUN

Green

On

Device enabled

Blinking

Device inhibited

IN1

Green

On

DI1 = HIGH

Off

DI1 = LOW

IN2

Green

On

DI2 = HIGH

Off

DI2 = LOW

...

...

...

...

IN7

Green

On

DI7 = HIGH

Off

DI7 = LOW

IN8

Green

On

DI8 = HIGH

Off

DI8 = LOW

OUT1

Yellow

On

DO1 = HIGH

Off

DO1 = LOW

OUT2

Yellow

On

DO2 = HIGH

Off

DO2 = LOW

OUT3

Yellow

On

DO3 = HIGH

Off

DO3 = LOW

OUT4

Yellow

On

DO4 = HIGH

Off

DO4 = LOW

Status display: fieldbus interface

Pos.

Colour

State

Description

BUS error

Red

On

Bus error (see plain text display)

Off

No bus error

BUS status

Green

Off

No communication with the PROFIBUS master

Blinking

The communication with the PROFIBUS master is established.

Status display: drive−based safety

Pos.

Colour

State

Description

SAFE status

Yellow

On

Safe torque off (STO) is active

Off

Safe torque off (STO) is not active

SAFE error

Red

On

System error:
After a serious internal error STO is activated.
Reset is only possible by switching the 24−V supply.

Off

Error−free operation

SAFE IN1

Green

On

The channels A and B are in the ON state.

Off

At least one channel is in the OFF state

SAFE IN2

Green

On

The channels A and B are in the ON state.

Off

At least one channel is in the OFF state

SAFE IN3

Green

Not active

SAFE IN4

Green

On

The channels A and B are in the ON state.

Off

At least one channel is in the OFF state

SO1

Yellow

Not active

SO2

Yellow

Advertising